Application

High voltage power cables are designed for transmitting electrical power at voltages above 150kV. These cables are crucial for power transmission and distribution networks, connecting power plants to substations and distributing electricity across vast distances.

Construction
  • Conductor: Copper
  • Conductor Screen: Semi-conductive tape+Semi-conductive Compound
  • Insulation: XLPE (Cross-linked Polyethylene)
  • Insulation Screen: Semi-conductive Compound
  • Wrapping: Semi-conductive water blocking tape
  • Metallic Screen: Copper wires
  • Tape: Aluminum plastic composite
  • Sheath: HDPE (High Density Polyethylene)
Main Characteristics
  • Operating Temperature: -30°C to +90°C
  • Short Circuit Temperature: +250°C
  • Overload Temperature: +130°C (100h per year maximum)
  • Minimum Installation Temperature: -20°C
Specification

IEC 62067, Power cables with extruded insulation and their accessories for rated voltages above 150 kV (U=170 kV) up to 500 kV.

Share:

Product Parameters

Nom. Cross-Section Area Nom. Insulation Thickness Metallic Screen Area Approx. Overall Diameter Approx. Weight
CU AL
mm2 mm mm2 mm kg/m kg/m
630 33 170 118 17 13
800 31 170 118 18 13
1000 29 170 118 20 14
1000 29 170 121 20 14
1200 27 170 120 22 14
1400 27 170 123 24 15
1600 37 170 127 26 16
1800 26 170 128 28 17
2000 26 170 131 30 18
2500 26 170 138 36 20

Application and case display

FAQ

Flame Retardant Cables VS Fire Resistant Cables?
What is the length tolerance for cables?
What is the minimum order quantity for the product?
What are the weight limits for different types of packages?
What is the purpose of a metallic shield in MV and HV cables?
What is the operating temperature of the cable?
The operating temperature of a cable is determined by the insulation and sheathing material. PVC has a range of -15°C to 70°C, XLPE can reach up to 90°C, while silicone rubber can handle temperatures from -60°C to 180°C.
How do you calculate the minimum bending radius of cables?
The bend radius refers to the curved shape in which an electrical cable can be bent or curved without sustaining damage. To determine the minimum bend radius for cables, apply the following formula: Minimum Bend Radius = Cable Outer Diameter×Cable Multiplier. For example, if the outer diameter of a cable is 20mm, its minimum bending radius would be 20mm×6 = 120mm. Conversely, if an armored cable has an outer diameter of 30mm, its minimum bending radius would be 30mm×12 = 360mm.
What is the minimum order quantity for the product?
The minimum order quantity for low and medium voltage cables is 200 meters, whereas for high voltage cables, it is 2000 meters. Should the order quantity fall below the MOQ, however, if the factory has stock, we can still supply it.
What is the purpose of a metallic shield in MV and HV cables?
Medium and high voltage power cables, typically those in circuits exceeding 2kV, usually feature a shield layer made of copper or aluminum tape. Similar to their use in low voltage cables, metallic wires and tapes are employed to prevent electromagnetic interference. These shields effectively neutralize or significantly diminish the field currents surrounding the conductor or core. The capacitive and inductive charging currents induced under normal operating conditions are subsequently grounded by the metallic screen.
Flame Retardant Cables VS Fire Resistant Cables?
Both types of cables are crucial in enhancing the likelihood of escape and survival in the event of a fire and are often confused with one another. However, there is a fundamental distinction between flame retardant cables and fire resistant cables. Flame retardant cables are engineered to inhibit the spread of fire to adjacent areas. On the other hand, fire resistant cables are specifically designed to preserve circuit integrity and ensure functionality during a fire, under specified conditions, aiding both evacuees and firefighters.

Get in Touch With Our Team

We're here to answer any questions you may have about our products, services, or technical specifications.
Address: No. 1207, Building B, No. 96 Kangning Street, Zhengdong New District, Zhengzhou, China

    your Name

    *

    your Email

    *

    your Phone

    your Whatsapp

    *

    Country

    Products&service

    Message

    *



    +86 371-63395670
    info@starsunelectric.com
    +86 19137160160
    Engineered for Excellence, Certified for Reliability – Power Cables That Meet IEC, ANATEL & INMETRO Standards Globally



      X