Home > Medium Voltage Power Cables > 6.35/11kV Three core Aluminum XLPE insulated Steel wire armored Cable
Three core Aluminum XLPE insulated Steel wire armored Cable
Three core Aluminum XLPE insulated Steel wire armored Cable

6.35/11kV Three core Aluminum XLPE insulated Steel wire armored Cable

Application

Medium voltage 6.35/11kV power cables are designed to be used for the supply of electrical energy in fixed applications up to the rated voltages at a nominal power frequency between 49Hz and 61Hz., they are suitable for use in distribution installation, electrical power station , they are applied for installation, outdoors, underground where subject to mechanical damage.

Construction
  • Conductor: Plain circular compacted aluminum
  • Conductor Screen: Extruded semi-conducting compound, bonded to the insulation and applied in the same operation as the insulation
  • Insulation: Cross Linked Polyethylene (XLPE)
  • Insulation Screen: Extruded semi-conducting compound
  • Metallic Screen: Plain annealed copper wire
  • Bedding: PVC
  • Armoured:Galvanized steel wires
  • Sheath: Polyvinyl chloride (PVC) – standard
Main Characteristics
  • Voltage Rating: 6.35/11(12)kV
  • Operating Temperature: 90°C
Specification

AS/NZS 1429.1:2006 Electric cables-Polymeric insulated Part 1: For working voltages 1.9/3.3 (3.6) kV up to and including 19/33 (36) kV.

Share:

Product Parameters

No.of Cores and Nominal Cross Section (AL) Nom. Conductor Diameter Nom. Insulation Thickness Nom. Diameter  Over insulation Screen Area on cores No. and Diameter of Screened Wires Nom. Diameter Over Screened Wires Nom. Diameter  Over Bedding Nom. Diameter of Armour Nom. Diameter  Over Armour Nom. Overall Diameter Approx. mass
mm² mm mm mm mm² no x mm mm mm mm mm mm kg/100m
3×35 6.9 3.4 14.9 23.8 14 x 0.85 18.2 42.6 2.5 47.6 53 415
3×50 8.1 3.4 16 32.3 19 x 0.85 19.3 45.2 2.5 50.2 55.8 460
3×70 9.6 3.4 17.6 46 27 x 0.85 20.9 48.9 2.5 53.9 59.7 530
3×95 11.4 3.4 19.3 61.3 36 x 0.85 22.6 52.8 2.5 57.8 63.8 610
3×120 12.8 3.4 20.7 68.1 40 x 0.85 24 55.8 2.5 60.8 67.2 675
3×150 14.2 3.4 22.1 68.1 40 x 0.85 25.4 59 2.5 64 70.7 730
3×185 15.7 3.4 23.6 68.1 40 x 0.85 26.9 62.3 2.5 67.3 74.1 800
3×240 18 3.4 25.9 68.1 40 x 0.85 29.2 67.4 3.15 73.7 81 990
3×300 20.1 3.4 28.3 68.1 40 x 0.85 31.6 72.6 3.15 78.9 86.6 1110
3×400 23 3.4 31.1 68.1 40 x 0.85 34.6 79.8 3.15 86.1 94.1 1290
3×500 26.5 3.4 34.7 68.1 40 x 0.85 38.2 87.6 3.15 93.9 102.4 1500

Application and case display

FAQ

How long is the validity period of cold shrink cable accessories?
What is the application of Armored vs. Unarmored Cables?
What are the weight limits for different types of packages?
What is the purpose of a metallic shield in MV and HV cables?
What is the minimum order quantity for the product?
How Do Water-Blocking Cables Work?
Water-blocking cables are essential for ensuring reliable operation in environments with high levels of moisture or frequent water contact. These cables employ water-blocking techniques to effectively prevent water ingress, protecting them from damage and prolonging their lifespan.
What temperature can high-temperature resistant cables reach, and what are their application scenarios?
High-temperature resistant cables are engineered to function within a wide temperature range, spanning from -50°C to +260°C, depending on the cable's specific type and construction. Silicone rubber-insulated cables can withstand temperatures up to 180°C, whereas fluoroplastic insulated cables are designed to endure temperatures as high as 200°C to 260°C over extended periods. They are widely used in steel metallurgy, power, petrochemicals, aerospace, and industrial kilns for power transmission and equipment control in high-heat environments.
What is the operating temperature of the cable?
The operating temperature of a cable is determined by the insulation and sheathing material. PVC has a range of -15°C to 70°C, XLPE can reach up to 90°C, while silicone rubber can handle temperatures from -60°C to 180°C.
How long is the validity period of cold shrink cable accessories?
The validity period for most cold shrink cable accessories is typically 3 years from the date of manufacture, provided they are stored under recommended conditions. These conditions usually include controlled humidity and temperature ranges.
What is the length tolerance for cables?
The tolerance for the power cable is 0 to +0.5%. For the bare conductor, the tolerance is ±5%.

Get in Touch With Our Team

We're here to answer any questions you may have about our products, services, or technical specifications.
Address: No. 1207, Building B, No. 96 Kangning Street, Zhengdong New District, Zhengzhou, China

    your Name

    *

    your Email

    *

    your Phone

    your Whatsapp

    *

    Country

    Products&service

    Message

    *



    +86 371-63395670
    info@starsunelectric.com
    +86 19137160160
    Engineered for Excellence, Certified for Reliability – Power Cables That Meet IEC, ANATEL & INMETRO Standards Globally



      X