FHLR2X Copper XLPE insulated Cable

Application

FHLR2X Cable is suitable for the connection between the motor and the electric control, between the electric control and the electric cabinet, between the battery and the electric cabinet and other components in the internal battery system.

Construction
  • Conductor:
    Bare: Cu-ETP1-A019/020-Pacc. to DIN EN 13602
    Tinned: Cu-ETP1-A017/018-Cacc. to DIN EN 13602
  • Insulation: XL-PE, Halogen Free
Main Characteristics
  • Service temperature: -40~125˚C
  • Heat resistance 1: 125˚C/3000h
  • Heat resistance 2: 150˚C/240h
  • Cold resistance: -40˚C/4h
  • Oil resistance: OK
  • Abrasion resistance: ISO 6722/19642
  • Flame resistance: ISO 6722/19642
Specification

ISO 19642 Road vehicles-Automotive cables
LV 216-2 Shielded High-voltage cables for motor vehicles and their electric drives

Share:

Product Parameters

Size Construction Conductor resistance (20℃) Insulation thickness Cable outside diameter
Number of strands Strand diameter Bare plated copper Sn plated copper
mm2 mm mΩ/m mm mm
max max min. max. min.
0.35 19 0.16 54.4 55.5 0.20 1.40 1.20
0.5 26 0.16 37.1 38.2 0.48 2.30 2.00
0.75 38 0.16 24.7 25.4 0.48 2.50 2.20
1 54 0.16 18.5 19.1 0.48 2.70 2.40
1.25 50 0.19 14.9 15.9 0.48 2.95 2.40
1.5 76 0.16 12.7 13.0 0.48 3.00 2.70
2 105 0.16 9.42 9.69 0.48 3.30 3.00
2.5 140 0.16 7.60 7.82 0.56 3.60 3.30
3 160 0.16 6.15 6.36 0.56 4.10 3.80
4 224 0.16 4.71 4.85 0.64 4.40 4.00
5 250 0.16 3.94 4.02 0.64 4.90 4.50
6 320 0.16 3.14 3.23 0.64 5.00 4.60
8 240 0.21 2.38 2.52 0.64 5.90 5.00
10 320 0.21 1.82 1.85 0.80 6.50 5.90
12 380 0.21 1.52 1.60 0.80 7.40 6.60
16 512 0.21 1.16 1.18 0.80 8.30 7.70
20 610 0.21 0.955 0.999 0.88 9.10 8.10
25 790 0.21 0.743 0.757 1.04 10.40 9.40
30 900 0.22 0.647 0.684 1.04 10.90 9.70
35 1070 0.21 0.527 0.538 1.04 11.60 9.60
40 1200 0.21 0.473 0.500 1.12 12.40 11.20
50 1600 0.21 0.368 0.375 1.20 13.50 11.50
60 1200 0.26 0.315 0.333 1.20 14.60 13.40
70 1427 0.26 0.259 0.264 1.20 15.50 13.50
85 2660 0.21 0.219 0.225 1.28 16.80 14.80
95 2450 0.26 0.196 0.200 1.28 18.00 16.00

Application and case display

FAQ

How do you calculate the minimum bending radius of cables?
What is the operating temperature of the cable?
Why do cable prices vary significantly among suppliers within the same region?
What are the benefits of EPR material?
Longitudinal Water Blocking vs. Lateral Water Blocking?
How long is the validity period of cold shrink cable accessories?
The validity period for most cold shrink cable accessories is typically 3 years from the date of manufacture, provided they are stored under recommended conditions. These conditions usually include controlled humidity and temperature ranges.
Is a flame-retardant cable also fire resistant?
No. A flame-retardant cable is not the same as a fire-resistant cable. A flame-retardant cable is designed to restrict the spread of fire by inhibiting combustion. Fire-resistant cables, on the other hand, maintain circuit integrity and continue to function for a specified time under defined fire conditions.
What is the operating temperature of the cable?
The operating temperature of a cable is determined by the insulation and sheathing material. PVC has a range of -15°C to 70°C, XLPE can reach up to 90°C, while silicone rubber can handle temperatures from -60°C to 180°C.
What is the service life of cables?
The design life of power cables is typically 20 to 30 years; however, this can vary significantly based on factors such as installation, environmental conditions, and the quality of the cable.
Longitudinal Water Blocking vs. Lateral Water Blocking?
A longitudinally water blocking cable is designed with a barrier to prevent the spread of moisture along its length. Longitudinal water blocking stops water from migrating along the cable's core, typically between the conductor strands, insulation layers, or metallic screens. Lateral water blocking ensures that water cannot penetrate the cable in the event that the sheathing is pierced or damaged. Radial water blocking prevents water from penetrating the cable's outer sheath or insulation layers, thereby stopping it from entering the cable structure entirely. Longitudinal water blocking can be achieved through various methods, including the application of water-blocking tapes and powders. These are frequently located on either side of a metallic screen and conductor. Lateral water blocking is typically accomplished by applying a layer of aluminum/polyester tape to the underside of the outer sheath.

Get in Touch With Our Team

We're here to answer any questions you may have about our products, services, or technical specifications.
Address: No. 1207, Building B, No. 96 Kangning Street, Zhengdong New District, Zhengzhou, China

    your Name

    *

    your Email

    *

    your Phone

    your Whatsapp

    *

    Country

    Products&service

    Message

    *



    +86 371-63395670
    info@starsunelectric.com
    +86 19137160160
    Engineered for Excellence, Certified for Reliability – Power Cables That Meet IEC, ANATEL & INMETRO Standards Globally



      X