Home > Control Cables > KVVP2 PVC insulated Copper tape shielded Control Cable
KVVP2 Control Cable
KVVP2 Control Cable

KVVP2 PVC insulated Copper tape shielded Control Cable

Application

KVVP2 Control Cable is applicable to AC rated voltage U0/ U is the control cable for fixed laying in control, monitoring circuit and protection circuit of (U0/U) 0.6/1kV and below.

Construction
  • Conductor: Copper, class 1, 2, or 5, solid,stranded round or soft conductor
  • Insulation: Polyvinyl chloride PVC
  • Filler: Non-hygroscopic material
  • Binder: Non-hygroscopic material
  • Metal shield: Copper tape
  • Outer sheath: Polyvinyl chloride PVC
Main Characteristics

Good electrical and mechanical properties. Resistance to abrasion, moisture and sunlight. Adequate resistance to oil and abrasion.

Specification

IEC 60228 Conductors of Insulate Cables
IEC 60502-1 Power Cables with Extruded Insulation and Their Accessories for Rated Voltages from 1kV(Um=1.2kV) up to 30kV(Um=36kV) – Part 1: Cables for Rated Voltages of 1kV (Um=1.2kV) and 3kV(Um=3.6kV)

Share:

Product Parameters

No. × section Insulation thickness Average diameter Min.insulation

Resistance

Conductor resistance at 20 ℃
KVVP2 KVVP3 KVVP2 KVVP3
Min. Max. Min. Max.
Mm2 mm mm mm mm mm MΩ*km Ω/km Ω/km
4×0.75 0.6 8.1 9.7 8.1 9.7 0.012 24.0 24.0
4×1.0 0.6 8.4 10.2 8.4 10.2 0.011 18.1 18.1
4×1.5 0.7 9.5 11.4 9.5 11.4 0.011 12.1 12.1
4×2.5 0.8 10.9 13.1 10.9 13.1 0.010 7.41 7.41
4×4 0.8 12.5 15.1 12.5 15.1 0.0085 4.61 4.61
4×6 0.8 13.6 16.5 13.6 16.5 0.0070 3.08 3.08
4×10 1.0 17.1 20.7 17.1 20.7 0.0065 1.83 1.83
5×0.75 0.6 8.6 10.4 8.6 10.4 0.012 24.0 24.0
5×1.0 0.6 9.0 10.9 9.0 10.9 0.011 18.1 18.1
5×1.5 0.7 10.2 12.3 10.2 12.3 0.011 12.1 12.1
5×2.5 0.8 11.8 14.2 11.8 14.2 0.010 7.41 7.41
5×4 0.8 13.5 16.3 13.5 16.3 0.0085 4.61 4.61
5×6 0.8 14.8 17.9 14.8 17.9 0.0070 3.08 3.08
5×10 1.0 19.1 23.0 19.1 23.0 0.0065 1.83 1.83
7×0.75 0.6 9.3 11.2 9.3 11.2 0.012 24.0 24.0
7×1.0 0.6 9.7 11.7 9.7 11.7 0.011 18.1 18.1
7×1.5 0.7 11.0 13.3 11.0 13.3 0.011 12.1 12.1
7×2.5 0.8 13.3 16.1 13.3 16.1 0.010 7.41 7.41
7×4 0.8 14.6 17.6 14.6 17.6 0.0085 4.61 4.61
7×6 0.8 16.0 19.4 16.0 19.4 0.0070 3.08 3.08
7×10 1.0 20.7 25.1 20.7 25.1 0.0065 1.83 1.83
8×0.75 0.6 10.2 12.3 10.2 12.3 0.012 24.0 24.0
8×1.0 0.6 10.7 12.9 10.7 12.9 0.011 18.1 18.1
8×1.5 0.7 12.8 15.4 12.8 15.4 0.011 12.1 12.1
8×2.5 0.8 14.7 17.8 14.7 17.8 0.010 7.41 7.41
8×4 0.8 16.2 19.6 16.2 19.6 0.0085 4.61 4.61
8×6 0.8 17.9 21.6 17.9 21.6 0.0070 3.08 3.08
8×10 1.0 23.2 28.1 23.2 28.1 0.0065 1.83 1.83
10×0.75 0.6 11.3 13.7 11.3 13.7 0.012 24.0 24.0
10×1.0 0.6 12.5 15.1 12.5 15.1 0.011 18.1 18.1
10×1.5 0.7 14.2 17.2 14.2 17.2 0.011 12.1 12.1
10×2.5 0.8 16.5 20.0 16.5 20.0 0.010 7.41 7.41
10×4 0.8 18.6 22.5 18.6 22.5 0.0085 4.61 4.61
10×6 0.8 20.5 24.8 20.5 24.8 0.0070 3.08 3.08
10×10 1.0 26.3 31.8 26.3 31.8 0.0065 1.83 1.83
12×0.75 0.6 11.7 14.1 11.7 14.1 0.012 24.0 24.0
12×1.0 0.6 12.8 15.5 12.8 15.5 0.011 18.1 18.1
12×1.5 0.7 14.6 17.7 14.6 17.7 0.011 12.1 12.1
12×2.5 0.8 17.0 20.6 17.0 20.6 0.010 7.41 7.41
12×4 0.8 19.2 23.2 19.2 23.2 0.0085 4.61 4.61
12×6 0.8 21.2 25.6 21.2 25.6 0.0070 3.08 3.08
14×0.75 0.6 12.2 14.7 12.2 14.7 0.012 24.0 24.0
14×1.0 0.6 13.4 16.2 13.4 16.2 0.011 18.1 18.1
14×1.5 0.7 15.3 18.5 15.3 18.5 0.011 12.1 12.1
14×2.5 0.8 17.8 21.5 17.8 21.5 0.010 7.41 7.41
14×4 0.8 20.1 24.3 20.1 24.3 0.0085 4.61 4.61
14×6 0.8 22.2 26.9 22.2 26.9 0.0070 3.08 3.08
16×0.75 0.6 13.3 16.1 13.3 16.1 0.012 24.0 24.0
16×1.0 0.6 14.0 16.9 14.0 16.9 0.011 18.1 18.1
16×1.5 0.7 16.1 19.4 16.1 19.4 0.011 12.1 12.1
16×2.5 0.8 19.1 23.1 19.1 23.1 0.010 7.41 7.41
19×0.75 0.6 14.0 16.9 14.0 16.9 0.012 24.0 24.0
19×1.0 0.6 14.7 17.7 14.7 17.7 0.011 18.1 18.1
19×1.5 0.7 16.8 20.4 16.8 20.4 0.011 12.1 12.1
19×2.5 0.8 20.1 24.3 20.1 24.3 0.010 7.41 7.41
24×0.75 0.6 16.0 19.4 16.0 19.4 0.012 24.0 24.0
24×1.0 0.6 16.9 20.4 16.9 20.4 0.011 18.1 18.1
24×1.5 0.7 19.9 24.0 19.9 24.0 0.011 12.1 12.1
24×2.5 0.8 23.3 28.2 23.3 28.2 0.010 7.41 7.41
27×0.75 0.6 16.3 19.7 16.3 19.7 0.012 24.0 24.0
27×1.0 0.6 17.2 20.8 17.2 20.8 0.011 18.1 18.1
27×1.5 0.7 20.3 24.5 20.3 24.5 0.011 12.1 12.1
27×2.5 0.8 23.8 28.8 23.8 28.8 0.010 7.41 7.41
30×0.75 0.6 16.9 20.4 16.9 20.4 0.012 24.0 24.0
30×1.0 0.6 17.8 21.5 17.8 21.5 0.011 18.1 18.1
30×1.5 0.7 21.0 25.3 21.0 25.3 0.011 12.1 12.1
30×2.5 0.8 24.6 29.8 24.6 29.8 0.010 7.41 7.41
37×0.75 0.6 18.1 21.9 18.1 21.9 0.012 24.0 24.0
37×1.0 0.6 19.5 23.5 19.5 23.5 0.011 18.1 18.1
37×1.5 0.7 22.5 27.2 22.5 27.2 0.011 12.1 12.1
37×2.5 0.8 26.5 32.1 26.5 32.1 0.010 7.41 7.41
44×0.75 0.6 20.5 24.8 20.5 24.8 0.012 24.0 24.0
44×1.0 0.6 21.7 26.2 21.7 26.2 0.011 18.1 18.1
44×1.5 0.7 25.2 30.4 25.2 30.4 0.011 12.1 12.1
44×2.5 0.8 30.3 36.7 30.3 36.7 0.010 7.41 7.41
48×0.75 0.6 20.9 25.2 20.9 25.2 0.012 24.0 24.0
48×1.0 0.6 22.0 26.6 22.0 26.6 0.011 18.1 18.1
48×1.5 0.7 25.5 30.9 25.5 30.9 0.011 12.1 12.1
48×2.5 0.8 30.8 37.2 30.8 37.2 0.010 7.41 7.41
52×0.75 0.6 21.4 25.8 21.4 25.8 0.012 24.0 24.0
52×1.0 0.6 22.6 27.3 22.6 27.3 0.011 18.1 18.1
52×1.5 0.7 26.2 31.7 26.2 31.7 0.011 12.1 12.1
52×2.5 0.8 31.7 38.2 31.7 38.2 0.010 7.41 7.41
61×0.75 0.6 22.6 27.3 22.6 27.3 0.012 24.0 24.0
61×1.0 0.6 23.9 28.9 23.9 28.9 0.011 18.1 18.1
61×1.5 0.7 28.4 34.3 28.4 34.3 0.011 12.1 12.1
61×2.5 0.8 33.9 41.0 33.9 41.0 0.010 7.41 7.41

Application and case display

FAQ

Longitudinal Water Blocking vs. Lateral Water Blocking?
What is the service life of cables?
How long is the validity period of cold shrink cable accessories?
How do you calculate the minimum bending radius of cables?
What is the minimum order quantity for the product?
What is the service life of cables?
The design life of power cables is typically 20 to 30 years; however, this can vary significantly based on factors such as installation, environmental conditions, and the quality of the cable.
How Do Water-Blocking Cables Work?
Water-blocking cables are essential for ensuring reliable operation in environments with high levels of moisture or frequent water contact. These cables employ water-blocking techniques to effectively prevent water ingress, protecting them from damage and prolonging their lifespan.
What is the operating temperature of the cable?
The operating temperature of a cable is determined by the insulation and sheathing material. PVC has a range of -15°C to 70°C, XLPE can reach up to 90°C, while silicone rubber can handle temperatures from -60°C to 180°C.
What temperature can high-temperature resistant cables reach, and what are their application scenarios?
High-temperature resistant cables are engineered to function within a wide temperature range, spanning from -50°C to +260°C, depending on the cable's specific type and construction. Silicone rubber-insulated cables can withstand temperatures up to 180°C, whereas fluoroplastic insulated cables are designed to endure temperatures as high as 200°C to 260°C over extended periods. They are widely used in steel metallurgy, power, petrochemicals, aerospace, and industrial kilns for power transmission and equipment control in high-heat environments.
Why do cable prices vary significantly among suppliers within the same region?
Cable prices vary due to differences in supplier strategies, competition, raw materials, and production processes, as well as after-sales services, including installation, equipment, and ongoing support.

Get in Touch With Our Team

We're here to answer any questions you may have about our products, services, or technical specifications.
Address: No. 1207, Building B, No. 96 Kangning Street, Zhengdong New District, Zhengzhou, China

    your Name

    your Email

    *

    Company Name

    *

    Country

    your Phone

    *

    WhatsApp No.

    Message

    *



    +86 371-63395670
    info@starsunelectric.com
    +86 13938540747
    Engineered for Excellence, Certified for Reliability – Power Cables That Meet IEC, ANATEL & INMETRO Standards Globally



      X