Home > Control Cables > KVVP2 PVC insulated Copper tape shielded Control Cable
KVVP2 Control Cable
KVVP2 Control Cable

KVVP2 PVC insulated Copper tape shielded Control Cable

Application

KVVP2 Control Cable is applicable to AC rated voltage U0/ U is the control cable for fixed laying in control, monitoring circuit and protection circuit of (U0/U) 0.6/1kV and below.

Construction
  • Conductor: Copper, class 1, 2, or 5, solid,stranded round or soft conductor
  • Insulation: Polyvinyl chloride PVC
  • Filler: Non-hygroscopic material
  • Binder: Non-hygroscopic material
  • Metal shield: Copper tape
  • Outer sheath: Polyvinyl chloride PVC
Main Characteristics

Good electrical and mechanical properties. Resistance to abrasion, moisture and sunlight. Adequate resistance to oil and abrasion.

Specification

IEC 60228 Conductors of Insulate Cables
IEC 60502-1 Power Cables with Extruded Insulation and Their Accessories for Rated Voltages from 1kV(Um=1.2kV) up to 30kV(Um=36kV) – Part 1: Cables for Rated Voltages of 1kV (Um=1.2kV) and 3kV(Um=3.6kV)

Share:

Product Parameters

No. × section Insulation thickness Average diameter Min.insulation

Resistance

Conductor resistance at 20 ℃
KVVP2 KVVP3 KVVP2 KVVP3
Min. Max. Min. Max.
Mm2 mm mm mm mm mm MΩ*km Ω/km Ω/km
4×0.75 0.6 8.1 9.7 8.1 9.7 0.012 24.0 24.0
4×1.0 0.6 8.4 10.2 8.4 10.2 0.011 18.1 18.1
4×1.5 0.7 9.5 11.4 9.5 11.4 0.011 12.1 12.1
4×2.5 0.8 10.9 13.1 10.9 13.1 0.010 7.41 7.41
4×4 0.8 12.5 15.1 12.5 15.1 0.0085 4.61 4.61
4×6 0.8 13.6 16.5 13.6 16.5 0.0070 3.08 3.08
4×10 1.0 17.1 20.7 17.1 20.7 0.0065 1.83 1.83
5×0.75 0.6 8.6 10.4 8.6 10.4 0.012 24.0 24.0
5×1.0 0.6 9.0 10.9 9.0 10.9 0.011 18.1 18.1
5×1.5 0.7 10.2 12.3 10.2 12.3 0.011 12.1 12.1
5×2.5 0.8 11.8 14.2 11.8 14.2 0.010 7.41 7.41
5×4 0.8 13.5 16.3 13.5 16.3 0.0085 4.61 4.61
5×6 0.8 14.8 17.9 14.8 17.9 0.0070 3.08 3.08
5×10 1.0 19.1 23.0 19.1 23.0 0.0065 1.83 1.83
7×0.75 0.6 9.3 11.2 9.3 11.2 0.012 24.0 24.0
7×1.0 0.6 9.7 11.7 9.7 11.7 0.011 18.1 18.1
7×1.5 0.7 11.0 13.3 11.0 13.3 0.011 12.1 12.1
7×2.5 0.8 13.3 16.1 13.3 16.1 0.010 7.41 7.41
7×4 0.8 14.6 17.6 14.6 17.6 0.0085 4.61 4.61
7×6 0.8 16.0 19.4 16.0 19.4 0.0070 3.08 3.08
7×10 1.0 20.7 25.1 20.7 25.1 0.0065 1.83 1.83
8×0.75 0.6 10.2 12.3 10.2 12.3 0.012 24.0 24.0
8×1.0 0.6 10.7 12.9 10.7 12.9 0.011 18.1 18.1
8×1.5 0.7 12.8 15.4 12.8 15.4 0.011 12.1 12.1
8×2.5 0.8 14.7 17.8 14.7 17.8 0.010 7.41 7.41
8×4 0.8 16.2 19.6 16.2 19.6 0.0085 4.61 4.61
8×6 0.8 17.9 21.6 17.9 21.6 0.0070 3.08 3.08
8×10 1.0 23.2 28.1 23.2 28.1 0.0065 1.83 1.83
10×0.75 0.6 11.3 13.7 11.3 13.7 0.012 24.0 24.0
10×1.0 0.6 12.5 15.1 12.5 15.1 0.011 18.1 18.1
10×1.5 0.7 14.2 17.2 14.2 17.2 0.011 12.1 12.1
10×2.5 0.8 16.5 20.0 16.5 20.0 0.010 7.41 7.41
10×4 0.8 18.6 22.5 18.6 22.5 0.0085 4.61 4.61
10×6 0.8 20.5 24.8 20.5 24.8 0.0070 3.08 3.08
10×10 1.0 26.3 31.8 26.3 31.8 0.0065 1.83 1.83
12×0.75 0.6 11.7 14.1 11.7 14.1 0.012 24.0 24.0
12×1.0 0.6 12.8 15.5 12.8 15.5 0.011 18.1 18.1
12×1.5 0.7 14.6 17.7 14.6 17.7 0.011 12.1 12.1
12×2.5 0.8 17.0 20.6 17.0 20.6 0.010 7.41 7.41
12×4 0.8 19.2 23.2 19.2 23.2 0.0085 4.61 4.61
12×6 0.8 21.2 25.6 21.2 25.6 0.0070 3.08 3.08
14×0.75 0.6 12.2 14.7 12.2 14.7 0.012 24.0 24.0
14×1.0 0.6 13.4 16.2 13.4 16.2 0.011 18.1 18.1
14×1.5 0.7 15.3 18.5 15.3 18.5 0.011 12.1 12.1
14×2.5 0.8 17.8 21.5 17.8 21.5 0.010 7.41 7.41
14×4 0.8 20.1 24.3 20.1 24.3 0.0085 4.61 4.61
14×6 0.8 22.2 26.9 22.2 26.9 0.0070 3.08 3.08
16×0.75 0.6 13.3 16.1 13.3 16.1 0.012 24.0 24.0
16×1.0 0.6 14.0 16.9 14.0 16.9 0.011 18.1 18.1
16×1.5 0.7 16.1 19.4 16.1 19.4 0.011 12.1 12.1
16×2.5 0.8 19.1 23.1 19.1 23.1 0.010 7.41 7.41
19×0.75 0.6 14.0 16.9 14.0 16.9 0.012 24.0 24.0
19×1.0 0.6 14.7 17.7 14.7 17.7 0.011 18.1 18.1
19×1.5 0.7 16.8 20.4 16.8 20.4 0.011 12.1 12.1
19×2.5 0.8 20.1 24.3 20.1 24.3 0.010 7.41 7.41
24×0.75 0.6 16.0 19.4 16.0 19.4 0.012 24.0 24.0
24×1.0 0.6 16.9 20.4 16.9 20.4 0.011 18.1 18.1
24×1.5 0.7 19.9 24.0 19.9 24.0 0.011 12.1 12.1
24×2.5 0.8 23.3 28.2 23.3 28.2 0.010 7.41 7.41
27×0.75 0.6 16.3 19.7 16.3 19.7 0.012 24.0 24.0
27×1.0 0.6 17.2 20.8 17.2 20.8 0.011 18.1 18.1
27×1.5 0.7 20.3 24.5 20.3 24.5 0.011 12.1 12.1
27×2.5 0.8 23.8 28.8 23.8 28.8 0.010 7.41 7.41
30×0.75 0.6 16.9 20.4 16.9 20.4 0.012 24.0 24.0
30×1.0 0.6 17.8 21.5 17.8 21.5 0.011 18.1 18.1
30×1.5 0.7 21.0 25.3 21.0 25.3 0.011 12.1 12.1
30×2.5 0.8 24.6 29.8 24.6 29.8 0.010 7.41 7.41
37×0.75 0.6 18.1 21.9 18.1 21.9 0.012 24.0 24.0
37×1.0 0.6 19.5 23.5 19.5 23.5 0.011 18.1 18.1
37×1.5 0.7 22.5 27.2 22.5 27.2 0.011 12.1 12.1
37×2.5 0.8 26.5 32.1 26.5 32.1 0.010 7.41 7.41
44×0.75 0.6 20.5 24.8 20.5 24.8 0.012 24.0 24.0
44×1.0 0.6 21.7 26.2 21.7 26.2 0.011 18.1 18.1
44×1.5 0.7 25.2 30.4 25.2 30.4 0.011 12.1 12.1
44×2.5 0.8 30.3 36.7 30.3 36.7 0.010 7.41 7.41
48×0.75 0.6 20.9 25.2 20.9 25.2 0.012 24.0 24.0
48×1.0 0.6 22.0 26.6 22.0 26.6 0.011 18.1 18.1
48×1.5 0.7 25.5 30.9 25.5 30.9 0.011 12.1 12.1
48×2.5 0.8 30.8 37.2 30.8 37.2 0.010 7.41 7.41
52×0.75 0.6 21.4 25.8 21.4 25.8 0.012 24.0 24.0
52×1.0 0.6 22.6 27.3 22.6 27.3 0.011 18.1 18.1
52×1.5 0.7 26.2 31.7 26.2 31.7 0.011 12.1 12.1
52×2.5 0.8 31.7 38.2 31.7 38.2 0.010 7.41 7.41
61×0.75 0.6 22.6 27.3 22.6 27.3 0.012 24.0 24.0
61×1.0 0.6 23.9 28.9 23.9 28.9 0.011 18.1 18.1
61×1.5 0.7 28.4 34.3 28.4 34.3 0.011 12.1 12.1
61×2.5 0.8 33.9 41.0 33.9 41.0 0.010 7.41 7.41

Application and case display

FAQ

What is the service life of cables?
What temperature can high-temperature resistant cables reach, and what are their application scenarios?
Longitudinal Water Blocking vs. Lateral Water Blocking?
Is a flame-retardant cable also fire resistant?
What is the minimum order quantity for the product?
What is the operating temperature of the cable?
The operating temperature of a cable is determined by the insulation and sheathing material. PVC has a range of -15°C to 70°C, XLPE can reach up to 90°C, while silicone rubber can handle temperatures from -60°C to 180°C.
What is the purpose of a metallic shield in MV and HV cables?
Medium and high voltage power cables, typically those in circuits exceeding 2kV, usually feature a shield layer made of copper or aluminum tape. Similar to their use in low voltage cables, metallic wires and tapes are employed to prevent electromagnetic interference. These shields effectively neutralize or significantly diminish the field currents surrounding the conductor or core. The capacitive and inductive charging currents induced under normal operating conditions are subsequently grounded by the metallic screen.
What temperature can high-temperature resistant cables reach, and what are their application scenarios?
High-temperature resistant cables are engineered to function within a wide temperature range, spanning from -50°C to +260°C, depending on the cable's specific type and construction. Silicone rubber-insulated cables can withstand temperatures up to 180°C, whereas fluoroplastic insulated cables are designed to endure temperatures as high as 200°C to 260°C over extended periods. They are widely used in steel metallurgy, power, petrochemicals, aerospace, and industrial kilns for power transmission and equipment control in high-heat environments.
Flame Retardant Cables VS Fire Resistant Cables?
Both types of cables are crucial in enhancing the likelihood of escape and survival in the event of a fire and are often confused with one another. However, there is a fundamental distinction between flame retardant cables and fire resistant cables. Flame retardant cables are engineered to inhibit the spread of fire to adjacent areas. On the other hand, fire resistant cables are specifically designed to preserve circuit integrity and ensure functionality during a fire, under specified conditions, aiding both evacuees and firefighters.
Longitudinal Water Blocking vs. Lateral Water Blocking?
A longitudinally water blocking cable is designed with a barrier to prevent the spread of moisture along its length. Longitudinal water blocking stops water from migrating along the cable's core, typically between the conductor strands, insulation layers, or metallic screens. Lateral water blocking ensures that water cannot penetrate the cable in the event that the sheathing is pierced or damaged. Radial water blocking prevents water from penetrating the cable's outer sheath or insulation layers, thereby stopping it from entering the cable structure entirely. Longitudinal water blocking can be achieved through various methods, including the application of water-blocking tapes and powders. These are frequently located on either side of a metallic screen and conductor. Lateral water blocking is typically accomplished by applying a layer of aluminum/polyester tape to the underside of the outer sheath.

Get in Touch With Our Team

We're here to answer any questions you may have about our products, services, or technical specifications.
Address: No. 1207, Building B, No. 96 Kangning Street, Zhengdong New District, Zhengzhou, China

    your Name

    *

    your Email

    *

    your Phone

    your Whatsapp

    *

    Country

    Products&service

    Message

    *



    +86 371-63395670
    info@starsunelectric.com
    +86 19137160160
    Engineered for Excellence, Certified for Reliability – Power Cables That Meet IEC, ANATEL & INMETRO Standards Globally



      X