Home > Control Cables > KYJV XLPE insulated Control Cable
7 Cores KYJV Control Cable
12 Cores KYJV Control Cable
19 Cores KYJV Control Cable
37 Cores KYJV Control Cables
7 Cores KYJV Control Cable
12 Cores KYJV Control Cable
19 Cores KYJV Control Cable
37 Cores KYJV Control Cables

KYJV XLPE insulated Control Cable

Application

KYJV Control Cable is applicable to control,monitoring circuit and protection circuit with AC rated voltage (0.6/1kV) or below.

Construction
  • Conductor:Copper,class 1,2,or 5,solid,stranded round or soft conductor
  • Insulation:Cross-linked polyethylene(XLPE)
  • Filler:Non-hygroscopic material
  • Binder:Non-hygroscopic material
  • Outer sheath:Polyvinyl chloride(PVC)
Main Characteristics
  • Good electrical and mechanical properties.Resistance to abrasion,moisture and sunlight.Adequate resistance to oil and abrasion.
Specification

IEC60228 Conductors of Insulated Cables
IEC 60502-1 Power Cables with Extruded Insulation and Their Accessories for Rated Voltages From 1kV (Um=1.2kV)up to 30kV(Um=36kV)-Part1:Cables for Rated Voltages of 1kV(Um=1.2kV)and 3kV(Um=3.6kV)

Share:

Product Parameters

No.of Cores and Nominal Cross Section Conductor Type Nominal Insulation Thickness Nominal Sheath Thickness Approx. Overall Diameter Approx. Weight Max.D.C. Resistance of Conductor at 20℃
No.×mm² mm mm mm kg/km Ω/km
2×0.5 2 0.6 1.8 8.1 71 36
2×0.75 2 0.6 1.8 8.5 85 24.5
2×1 2 0.6 1.8 8.9 94 18.1
2×1.5 2 0.7 1.8 9.9 120 12.1
2×2.5 2 0.7 1.8 10.7 145 7.41
2×4 2 0.7 1.8 11.8 187 4.61
2×6 2 0.7 1.8 12.9 233 3.08
2×10 2 0.7 1.8 14.7 346 1.83
3×0.5 2 0.6 1.8 8.4 84 36
3×0.75 2 0.6 1.8 8.9 104 24.5
3×1 2 0.6 1.8 9.3 115 18.1
3×1.5 2 0.7 1.8 10.4 138 12.1
3×2.5 2 0.7 1.8 11.3 174 7.41
3×4 2 0.7 1.8 12.4 232 4.61
3×6 2 0.7 1.8 13.6 304 3.08
3×10 2 0.7 1.8 15.5 454 1.83
4×0.5 2 0.6 1.8 9 91 36
4×0.75 2 0.6 1.8 9.5 106 24.5
4×1 2 0.6 1.8 9.9 131 18.1
4×1.5 2 0.7 1.8 11.1 171 12.1
4×2.5 2 0.7 1.8 12.2 217 7.41
4×4 2 0.7 1.8 13.5 293 4.61
4×6 2 0.7 1.8 14.8 389 3.08
4×10 2 0.7 1.8 16.9 599 1.83
5×0.5 2 0.6 1.8 9.6 103 36
5×0.75 2 0.6 1.8 10.1 134 24.5
5×1 2 0.6 18 10.6 152 18.1
5×1.5 2 0.7 1.8 12 195 12.1
5×2.5 2 0.7 1.8 13.1 257 7.41
5×4 2 0.7 1.8 14.6 351 4.61
5×6 2 0.7 1.8 16 455 3.08
5×10 2 0.7 1.8 18.5 719 1.83
6×0.5 2 0.6 1.8 10.2 116 36
6×0.75 2 0.6 1.8 10.8 137 24.5
6×1 2 0.6 1.8 11.4 159 18.1
6×1.5 2 0.7 1.8 12.9 210 12.1
6×2.5 2 0.7 1.8 14.1 277 7.41
6×4 2 0.7 1.8 15.8 382 4.61
6×6 2 0.7 1.8 17.4 515 3.08
6×10 2 0.7 1.8 20.1 773 1.83
7×0.5 2 0.6 1.8 10.2 120 36
7×0.75 2 0.6 1.8 10.8 145 24.5
7×1 2 0.6 1.8 11.4 169 18.1
7×1.5 2 0.7 1.8 12.9 226 12.1
7×2.5 2 0.7 1.8 14.1 303 7.41
7×4 2 0.7 1.8 15.8 422 4.61
7×6 2 0.7 1.8 17.4 565 3.08
7×10 2 0.7 1.8 20.1 854 1.83
8×0.5 2 0.6 1.8 11.1 138 36
8×0.75 2 0.6 1.8 11.9 166 24.5
8×1 2 0.6 1.8 12.5 195 18.1
8×1.5 2 0.7 1.8 14.2 260 12.1
8×2.5 2 0.7 1.8 15.7 348 7.41
8×4 2 0.7 1.8 17.5 487 4.61
8×6 2 0.7 1.8 19.4 650 3.08
8×10 2 0.7 1.8 22.5 987 1.83
9×0.5 2 0.6 1.8 11.9 154 36
9×0.75 2 0.6 1.8 12.7 188 24.5
9×1 2 0.6 1.8 13.4 219 18.1
9×1.5 2 0.7 1.8 15.3 292 12.1
9×2.5 2 0.7 1.8 16.9 393 7.41
9×4 2 0.7 1.8 18.9 549 4.61
9×6 2 0.7 1.8 21 739 3.08
9×10 2 0.7 1.8 24.4 1122 1.83
10×0.5 2 0.6 1.8 12.3 165 36
10×0.75 2 0.6 1.8 13.1 200 24.5
10×1 2 0.6 1.8 13.9 233 18.1
10×1.5 2 0.7 1.8 15.9 313 12.1
10×2.5 2 0.7 1.8 17.5 424 7.41
10×4 2 0.7 1.8 19.7 595 4.61
10×6 2 0.7 1.8 21.9 802 3.08
10×10 2 0.7 1.8 25.5 1216 1.83
12×0.5 2 0.6 1.8 12.6 177 36
12×0.75 2 0.6 1.8 13.5 218 24.5
12×1 2 0.6 1.8 14.3 258 18.1
12×1.5 2 0.7 1.8 16.3 351 12.1
12×2.5 2 0.7 1.8 18.1 479 7.41
12×4 2 0.7 1.8 20.3 679 4.61
12×6 2 0.7 1.8 22.6 919 3.08
14×0.5 2 0.6 1.8 13.2 196 36
14×0.75 2 0.6 1.8 14.1 243 24.5
14×1 2 0.6 1.8 14.9 289 18.1
14×1.5 2 0.7 1.8 17.1 396 12.1
14×2.5 2 0.7 1.8 18.9 544 7.41
14×4 2 0.7 1.8 21.3 775 4.61
14×6 2 0.7 1.8 23.7 1053 308
16×0.5 2 0.6 1.8 13.8 219 36
16×0.75 2 0.6 1.8 14.8 271 24.5
16×1 2 0.6 1.8 15.6 323 18.1
16×1.5 2 0.7 1.8 18 444 12.1
16×2.5 2 0.7 1.8 19.9 613 7.41
16×4 2 0.7 1.8 22.5 877 4.61
16×6 2 0.7 1.8 25 1193 3.08
19×0.5 2 0.6 1.8 14.4 243 36
19×0.75 2 0.6 1.8 15.5 305 24.5
19×1 2 0.6 1.8 16.4 365 18.1
19×1.5 2 0.7 1.8 18.9 506 12.1
19×2.5 2 0.7 1.8 21 704 7.41
19×4 2 0.7 1.8 23.7 1014 4.61
19×6 2 0.7 1.8 26.4 1387 3.08
20×0.5 2 0.6 18 15.1 256 36
20×0.75 2 0.6 1.8 16.2 321 24.5
20×1 2 0.6 1.8 17.2 385 18.1
20×1.5 2 0.7 1.8 19.8 534 12.1
20×2.5 2 0.7 1.8 22.1 742 7.41
20×4 2 0.7 1.8 25 1069 4.61
20×6 2 0.7 1.8 27.8 1462 3.08
21×0.5 2 0.6 1.8 15.1 264 36
21×0.75 2 0.6 1.8 16.2 332 24.5
21×1 2 0.6 1.8 17.2 398 18.1
21×1.5 2 0.7 1.8 19.8 553 12.1
21×2.5 2 0.7 1.8 22.1 771 7.41
21×4 2 0.7 1.8 25 1113 4.61
21×6 2 0.7 1.8 27.8 1524 3.08
22×0.5 2 0.6 1.8 15.8 277 36
22×0.75 2 0.6 1.8 17 348 24.5
22×1 2 0.6 1.8 18 418 18.1
22×1.5 2 0.7 1.8 20.9 581 12.1
22×2.5 2 0.7 1.8 23.2 809 7.41
22×4 2 0.7 1.8 26.3 1168 4.61
22×6 2 0.7 1.9 29.9 1620 3.08
24×0.5 2 0.6 1.8 16.5 303 36
24×0.75 2 0.6 1.8 17.8 380 24.5
24×1 2 0.6 1.8 18.8 456 18.1
24×1.5 2 0.7 1.8 21.8 633 12.1
24×2.5 2 0.7 1.8 24.4 883 7.41
24×4 2 0.7 1.8 27.6 1275 4.61
24×6 2 0.7 1.9 31.3 1771 3.08
27×0.5 2 0.6 1.8 16.8 322 36
27×0.75 2 0.6 1.8 18.1 408 24.5
27×1 2 0.6 1.8 19.2 492 18.1
27×1.5 2 0.7 1.8 22.3 689 12.1
27×2.5 2 0.7 1.8 24.9 967 7.41
27×4 2 0.7 1.8 28.2 1403 4.61
27×6 2 0.7 1.9 32 1951 3.08
30×0.5 2 0.6 1.8 17.4 349 36
30×0.75 2 0.6 1.8 18.7 443 24.5
30×1 2 0.6 1.8 19.9 536 18.1
30×1.5 2 0.7 1.8 23.1 753 12.1
30×2.5 2 0.7 1.8 25.8 1060 7.41
30×4 2 0.7 1.9 29.7 1564 4.61
30×6 2 0.7 2 33.4 2164 3.08
33×0.5 2 0.6 1.8 18 378 36
33×0.75 2 0.6 1.8 19.4 482 24.5
33×1 2 0.6 1.8 20.6 584 18.1
33×1.5 2 0.7 1.8 23.9 821 12.1
33×2.5 2 0.7 1.8 26.7 1158 7.41
33×4 2 0.7 1.9 30.9 1711 4.61
33×6 2 0.7 2 34.7 2368 3.08
37×0.5 2 0.6 1.8 18.6 411 36
37×0.75 2 0.6 1.8 20.1 526 24.5
37×1 2 0.6 1.8 21.3 639 18.1
37×1.5 2 0.7 1.8 24.8 903 12.1
37×2.5 2 0.7 1.8 27.8 1278 7.41
37×4 2 0.7 1.9 32.1 1892 4.61
37×6 2 0.7 2.1 36.2 2641 3.08
44×0.5 2 0.6 1.8 20.7 485 36
44×0.75 2 0.6 1.8 22.4 621 24.5
44×1 2 0.6 1.8 23.8 755 18.1
44×1.5 2 0.7 1.8 27.8 1067 12.1
44×2.5 2 0.7 1.9 31.7 1537 7.41
44×4 2 0.7 2.1 36.4 2276 4.61
44×6 2 0.7 2.2 40.9 3153 3.08
48×0.5 2 0.6 1.8 21 511 36
48×0.75 2 0.6 1.8 22.7 659 24.5
48×1 2 0.6 1.8 24.2 805 18.1
48×1.5 2 0.7 1.8 28.3 1143 12.1
48×2.5 2 0.7 1.9 32.2 1650 7.41
48×4 2 0.7 2.1 37 2449 4.61
48×6 2 0.7 2.2 41.6 3396 3.08
52×0.5 2 0.6 1.8 21.6 545 36
52×0.75 2 0.6 1.8 23.3 705 24.5
52×1 2 0.6 1.8 24.8 862 18.1
52×1.5 2 0.7 1.9 29.5 1248 12.1
52×2.5 2 0.7 2 33.3 1788 7.41
52×4 2 0.7 2.1 38 2634 4.61
52×6 2 0.7 2.3 43 3677 3.08
61×0.5 2 0.6 1.8 22.8 622 36
61×0.75 2 0.6 1.8 24.7 807 24.5
61×1 2 0.6 1.8 26.3 991 18.1
61×1.5 2 0.7 1.9 31.3 1437 12.1
61×2.5 2 0.7 2 35.3 2065 7.41
61×4 2 0.7 2.2 40.6 3071 4.61
61×6 2 0.7 2.4 45.8 4287 3.08

Application and case display

FAQ

What is the service life of cables?
How long is the validity period of cold shrink cable accessories?
How do you calculate the minimum bending radius of cables?
Is a flame-retardant cable also fire resistant?
What temperature can high-temperature resistant cables reach, and what are their application scenarios?
What are the weight limits for different types of packages?
The weight limit for a wooden drum or steel wooden is 5,000 kg, and for a steel drum, it is 10,000 kg.
Flame Retardant Cables VS Fire Resistant Cables?
Both types of cables are crucial in enhancing the likelihood of escape and survival in the event of a fire and are often confused with one another. However, there is a fundamental distinction between flame retardant cables and fire resistant cables. Flame retardant cables are engineered to inhibit the spread of fire to adjacent areas. On the other hand, fire resistant cables are specifically designed to preserve circuit integrity and ensure functionality during a fire, under specified conditions, aiding both evacuees and firefighters.
Longitudinal Water Blocking vs. Lateral Water Blocking?
A longitudinally water blocking cable is designed with a barrier to prevent the spread of moisture along its length. Longitudinal water blocking stops water from migrating along the cable's core, typically between the conductor strands, insulation layers, or metallic screens. Lateral water blocking ensures that water cannot penetrate the cable in the event that the sheathing is pierced or damaged. Radial water blocking prevents water from penetrating the cable's outer sheath or insulation layers, thereby stopping it from entering the cable structure entirely. Longitudinal water blocking can be achieved through various methods, including the application of water-blocking tapes and powders. These are frequently located on either side of a metallic screen and conductor. Lateral water blocking is typically accomplished by applying a layer of aluminum/polyester tape to the underside of the outer sheath.
Is a flame-retardant cable also fire resistant?
No. A flame-retardant cable is not the same as a fire-resistant cable. A flame-retardant cable is designed to restrict the spread of fire by inhibiting combustion. Fire-resistant cables, on the other hand, maintain circuit integrity and continue to function for a specified time under defined fire conditions.
What temperature can high-temperature resistant cables reach, and what are their application scenarios?
High-temperature resistant cables are engineered to function within a wide temperature range, spanning from -50°C to +260°C, depending on the cable's specific type and construction. Silicone rubber-insulated cables can withstand temperatures up to 180°C, whereas fluoroplastic insulated cables are designed to endure temperatures as high as 200°C to 260°C over extended periods. They are widely used in steel metallurgy, power, petrochemicals, aerospace, and industrial kilns for power transmission and equipment control in high-heat environments.

Get in Touch With Our Team

We're here to answer any questions you may have about our products, services, or technical specifications.
Address: No. 1207, Building B, No. 96 Kangning Street, Zhengdong New District, Zhengzhou, China

    your Name

    your Email

    *

    Company Name

    *

    Country

    your Phone

    *

    WhatsApp No.

    Message

    *



    +86 371-63395670
    info@starsunelectric.com
    +86 13938540747
    Engineered for Excellence, Certified for Reliability – Power Cables That Meet IEC, ANATEL & INMETRO Standards Globally