Home > Medium Voltage Power Cables > MV-105: Cable de cobre blindado de 35 kV con aislamiento EPR 100% / 133%
MV105 Cable
MV105 Cable

MV-105: Cable de cobre blindado de 35 kV con aislamiento EPR 100% / 133%

Aplicación

Estos cables se utilizan en sistemas de redes de distribución primaria en áreas residenciales, comerciales e industriales.Se pueden utilizar en tuberías de conducto, ductos subterráneos o directamente enterrados.

Construcción
  • Conductor: Cobre, conductores trenzados circulares comprimidos o compactados.
  • Pantalla del conductor: Compuesto semiconductor no metálico.
  • Aislamiento: Niveles de aislamiento del 100%, 133% y 173%, caucho de etileno-propileno (EPR).
  • Pantalla del aislamiento: Compuesto semiconductor no metálico.
  • Pantalla metálica: Cinta de cobre.
  • Cubierta exterior: Resistente a la luz solar, policloruro de vinilo (PVC) o polietileno (PE) o poliolefina (PO).
Parámetros del Producto
  • Temperatura máxima del conductor en operación normal: 90°C.
  • Temperatura de sobrecarga de emergencia: No debe exceder los 130°C.
  • Temperatura de cortocircuito (duración máxima de 5 segundos): No debe exceder los 250°C.
  • Opciones de fabricación del producto: Elementos de bloqueo contra la penetración de agua en la parte metálica para ambientes húmedos y mojados.
Especificación

ASTM B 8 Standard Specification for Concentric – Lay – Stranded Copper Conductors, Hard, Medium – Hard, or Soft

ASTM B 496 Compact Round Concentric – Lay – Stranded Copper Conductors

ANSI/NEMA WC 74/ICEAS-93-639 5-46KV Shielded Power Cable for Use in the Transmission and Distribution of Electric Energy

UL1072 Medium Voltage Power Cable

Share:

Parámetros del Producto

Conductor Nivel de Aislamiento 100% Nivel de Aislamiento 133%
Tamaño Área Diám. Nom. Espesor Ais. 100% Espesor Cubierta 100% Diám. Total 100% Peso 100% Espesor Ais. 133% Espesor Cubierta 133% Diám. Total 133% Peso 133%
AWG/kcmil mm² mm mm mm mm kg/km mm mm mm kg/km
1/0 53.5 8.53 8.76 2.03 35.7 1610 10.67 2.03 39.2 1831
2/0 67.4 9.55 8.76 2.03 36.7 1786 10.67 2.03 40.2 2012
3/0 85 10.7 8.76 2.03 37.8 2002 10.67 2.03 41.4 2234
4/0 107 12.1 8.76 2.03 39.2 2271 10.67 2.03 42.8 2510
250 127 13.2 8.76 2.03 40.3 2503 10.67 2.03 43.9 2748
350 177 15.6 8.76 2.03 42.7 3080 10.67 2.03 46.3 3338
500 253 18.7 8.76 2.03 45.8 3922 10.67 2.79 51.2 4398
750 380 23.1 8.76 2.79 52 5495 10.67 2.79 55.6 5805
1000 507 26.9 8.76 2.79 56.2 6868 10.67 2.79 59.7 7200
1250 633 31.8 8.76 2.79 61.1 8283 10.67 2.79 64.6 8641

Application and case display

FAQ

How do you calculate the minimum bending radius of cables?
What are the benefits of EPR material?
What are the weight limits for different types of packages?
What is the length tolerance for cables?
What is the minimum order quantity for the product?
What is the operating temperature of the cable?
How do you calculate the minimum bending radius of cables?
The bend radius refers to the curved shape in which an electrical cable can be bent or curved without sustaining damage. To determine the minimum bend radius for cables, apply the following formula: Minimum Bend Radius = Cable Outer Diameter×Cable Multiplier. For example, if the outer diameter of a cable is 20mm, its minimum bending radius would be 20mm×6 = 120mm. Conversely, if an armored cable has an outer diameter of 30mm, its minimum bending radius would be 30mm×12 = 360mm.
What are the benefits of EPR material?
EPR is widely used as an insulation material for electric cables due to its high dielectric strength, and it also serves as a sheathing material with excellent ozone and weathering resistance. EPR has a wide thermal range, typically spanning from -55°C to 150°C. Unlike other organic rubbers, there is no need to tin the copper conductor to prevent deterioration of the rubber.
What are the weight limits for different types of packages?
The weight limit for a wooden drum or steel wooden is 5,000 kg, and for a steel drum, it is 10,000 kg.
What is the length tolerance for cables?
The tolerance for the power cable is 0 to +0.5%. For the bare conductor, the tolerance is ±5%.
What is the minimum order quantity for the product?
The minimum order quantity for low and medium voltage cables is 200 meters, whereas for high voltage cables, it is 2000 meters. Should the order quantity fall below the MOQ, however, if the factory has stock, we can still supply it.
What is the operating temperature of the cable?
The operating temperature of a cable is determined by the insulation and sheathing material. PVC has a range of -15°C to 70°C, XLPE can reach up to 90°C, while silicone rubber can handle temperatures from -60°C to 180°C.

Get in Touch With Our Team

We're here to answer any questions you may have about our products, services, or technical specifications.
Address: No. 1207, Building B, No. 96 Kangning Street, Zhengdong New District, Zhengzhou, China

    your Name

    your Email

    *

    Company Name

    *

    Country

    your Phone

    *

    WhatsApp No.

    Message

    *



    +86 371-63395670
    info@starsunelectric.com
    +86 13938540747
    Engineered for Excellence, Certified for Reliability – Power Cables That Meet IEC, ANATEL & INMETRO Standards Globally



      X