Home > Medium Voltage Power Cables > N2XSBY 3.6/6 (7.2) kV Copper XLPE insulated Steel tape armored Cable
N2XSBY-Cable
N2XSBY-Cable

N2XSBY 3.6/6 (7.2) kV Copper XLPE insulated Steel tape armored Cable

Application

Medium voltage cables for distribution networks.They are suitable for laying indoor,tunnel,cables trench and underground,it is able to bear external mechanical forces,but unable to bear heavy pulling force,it widely used in transformer stations,electric power plants and industrial plants.

Construction
  • Conductor: Copper,class2,circular compacted conductors
  • Conductor screen: Non-metallic,semi-conducting compound
  • Insulation: Cross-linked polyethylene (XLPE)
  • Insulation screen: Non-metallic,semi-conducting compound
  • Metallic screen: Copper tape
  • Inner sheath: Polyvinyl chloride(PVC)
  • Armour: Non-magnetic steel tape
  • Outer sheath: Polyvinyl chloride(PVC)
Main Characteristics
  • Good electrical and mechanical properties.
  • Minimal dielectric loss,high insulation resistance.
Specification

IEC 60228 Conductors of Insulated Cables.
Rated Voltages: from 6kV(Um=7.2kV) up to 30kV (Um=36kV)

Share:

Product Parameters

No.of Cores and Nominal Cross Section Nominal Insulation Thickness Nominal Steel Tape Thickness Nominal Sheath Thickness Approx. Overall Diameter Approx.Weight Max.D.C.
Resistance of Conductor at 20℃
Cu Al Cu Al
mm² mm mm mm mm kg/km kg/km Ω/km Ω/km
1×25 2.5 0.2 1.6 20.2 728 576 0.727 1.2
1×35 2.5 0.2 1.6 21.2 849 638 0.524 0.868
1×50 2.5 0.2 1.7 22.5 1006 720 0.387 0.641
1×70 2.5 0.2 1.7 24.2 1252 837 0.268 0.443
1×95 2.5 0.2 1.8 26.2 1559 985 0.193 0.32
1×120 2.5 0.2 1.8 27.4 1819 1093 0.153 0.253
1×150 2.5 0.2 1.9 29.1 2130 1233 0.124 0.206
1×185 2.5 0.2 1.9 30.8 2524 1394 0.0991 0.164
1×240 2.6 0.2 2 33.5 3130 1663 0.0754 0.125
1×300 2.8 0.5 2.2 37.7 4161 2322 0.0601 0.1
1×400 3 0.5 2.3 41 5109 2740 0.047 0.0778
1×500 3.2 0.5 2.4 45.2 6290 3283 0.0366 0.0605
1×630 3.2 0.5 2.5 49.3 7813 3909 0.0283 0.0469

Application and case display

FAQ

What is the purpose of a metallic shield in MV and HV cables?
What is the service life of cables?
What is the validity period for the offer of cable?
What temperature can high-temperature resistant cables reach, and what are their application scenarios?
How Do Water-Blocking Cables Work?
Why do cable prices vary significantly among suppliers within the same region?
Cable prices vary due to differences in supplier strategies, competition, raw materials, and production processes, as well as after-sales services, including installation, equipment, and ongoing support.
What is the service life of cables?
The design life of power cables is typically 20 to 30 years; however, this can vary significantly based on factors such as installation, environmental conditions, and the quality of the cable.
Longitudinal Water Blocking vs. Lateral Water Blocking?
A longitudinally water blocking cable is designed with a barrier to prevent the spread of moisture along its length. Longitudinal water blocking stops water from migrating along the cable's core, typically between the conductor strands, insulation layers, or metallic screens. Lateral water blocking ensures that water cannot penetrate the cable in the event that the sheathing is pierced or damaged. Radial water blocking prevents water from penetrating the cable's outer sheath or insulation layers, thereby stopping it from entering the cable structure entirely. Longitudinal water blocking can be achieved through various methods, including the application of water-blocking tapes and powders. These are frequently located on either side of a metallic screen and conductor. Lateral water blocking is typically accomplished by applying a layer of aluminum/polyester tape to the underside of the outer sheath.
What are the benefits of EPR material?
EPR is widely used as an insulation material for electric cables due to its high dielectric strength, and it also serves as a sheathing material with excellent ozone and weathering resistance. EPR has a wide thermal range, typically spanning from -55°C to 150°C. Unlike other organic rubbers, there is no need to tin the copper conductor to prevent deterioration of the rubber.
What is the validity period for the offer of cable?
Typically, the offer is valid for 7 to 30 days, and the price will be adjusted according to the cost of raw materials and the exchange rate.

Get in Touch With Our Team

We're here to answer any questions you may have about our products, services, or technical specifications.
Address: No. 1207, Building B, No. 96 Kangning Street, Zhengdong New District, Zhengzhou, China

    your Name

    *

    your Email

    *

    your Phone

    your Whatsapp

    *

    Country

    Products&service

    Message

    *



    +86 371-63395670
    info@starsunelectric.com
    +86 19137160160
    Engineered for Excellence, Certified for Reliability – Power Cables That Meet IEC, ANATEL & INMETRO Standards Globally



      X