Home > Medium Voltage Power Cables > Single Core Copper XLPE CWS Non-Magnetic STA PVC MV Cable 8.7/15kV
N2XSBY-Cable
N2XSBY-Cable

Single Core Copper XLPE CWS Non-Magnetic STA PVC MV Cable 8.7/15kV

Application

Medium voltage N2XSBY cables for distribution networks.They are suitable for laying indoor,tunnel,cables trench and underground,it is able to bear external mechanical forces,but unable to bear heavy pulling force,it widely used in transformer stations,electric power plants and industrial plants.

Construction
  • Conductor:Copper,class 2,circular compacted conductors
  • Conductor screen:Non-metallic,semi-conducting compound
  • Insulation:Cross -linked polyethylene (XLPE)
  • Insulation screen:Non-metallic,semi-conducting compound
  • Metallic screen:Copper wire
  • Inner sheath:Polyvinyl chloride(PVC)
  • Armour:Non-magnetic steel tape
  • Outer sheath:Polyvinyl chloride(PVC)
Main Characteristics
  • Good electrical and mechanical properties.
  • Minimal dielectric loss,high insulation resistance.
Specification

IEC60228 Conductors of Insulated Cables
IEC 60502-2 Power Cables with Extruded Insulation and Their Accessories for Rated Voltages from1kV (Um=1.2KV)up to 30kV(Um=36KV)-Part 2:Cables for Rated Voltages of 6kV(Um=7.2KV)up to 30kV (Um=36kV).

Share:

Product Parameters

No.of Cores and Nominal Cross Section Nominal Insulation Thickness Nominal Steel Tape Thickness Nominal Sheath Thickness Approx. Overall Diameter Approx.Weight Max.D.C.Resistance of Conductor at 20℃
Cu Al Cu Al
mm² mm mm mm mm kg/km kg/km Ω/km Ω/km
1×25 4.5 0.20 1.8 26.8 1093 941 0.727 1.2
1×35 4.5 0.20 1.8 27.8 1219 1008 0.524 0.868
1×50 4.5 0.20 1.9 29.1 1384 1098 0.387 0.641
1×70 4.5 0.20 1.9 30.8 1637 1223 0.268 0.443
1×95 4.5 0.20 2.0 32.8 1955 1381 0.193 0.32
1×120 4.5 0.20 2 34 2221 1495 0.153 0.253
1×150 4.5 0.20 2.1 35.7 2628 1724 0.124 0.206
1×185 4.5 0.20 2.1 38.8 3411 2273 0.0991 0.164
1×240 4.5 0.50 2.2 41.1 4024 2549 0.0754 0.125
1×300 4.5 0.50 2.2 43.7 4713 2826 0.0601 0.100
1×400 4.5 0.50 2.4 46.6 5734 3358 0.047 0.0778
1×500 4.5 0.50 2.5 50.5 6901 3886 0.0366 0.0605
1×630 4.5 0.50 2.6 54.4 8408 4497 0.0283 0.0469

Application and case display

FAQ

Flame Retardant Cables VS Fire Resistant Cables?
What is the purpose of a metallic shield in MV and HV cables?
What temperature can high-temperature resistant cables reach, and what are their application scenarios?
How do you calculate the minimum bending radius of cables?
Why do cable prices vary significantly among suppliers within the same region?
Flame Retardant Cables VS Fire Resistant Cables?
Both types of cables are crucial in enhancing the likelihood of escape and survival in the event of a fire and are often confused with one another. However, there is a fundamental distinction between flame retardant cables and fire resistant cables. Flame retardant cables are engineered to inhibit the spread of fire to adjacent areas. On the other hand, fire resistant cables are specifically designed to preserve circuit integrity and ensure functionality during a fire, under specified conditions, aiding both evacuees and firefighters.
What is the purpose of a metallic shield in MV and HV cables?
Medium and high voltage power cables, typically those in circuits exceeding 2kV, usually feature a shield layer made of copper or aluminum tape. Similar to their use in low voltage cables, metallic wires and tapes are employed to prevent electromagnetic interference. These shields effectively neutralize or significantly diminish the field currents surrounding the conductor or core. The capacitive and inductive charging currents induced under normal operating conditions are subsequently grounded by the metallic screen.
What temperature can high-temperature resistant cables reach, and what are their application scenarios?
High-temperature resistant cables are engineered to function within a wide temperature range, spanning from -50°C to +260°C, depending on the cable's specific type and construction. Silicone rubber-insulated cables can withstand temperatures up to 180°C, whereas fluoroplastic insulated cables are designed to endure temperatures as high as 200°C to 260°C over extended periods. They are widely used in steel metallurgy, power, petrochemicals, aerospace, and industrial kilns for power transmission and equipment control in high-heat environments.
How do you calculate the minimum bending radius of cables?
The bend radius refers to the curved shape in which an electrical cable can be bent or curved without sustaining damage. To determine the minimum bend radius for cables, apply the following formula: Minimum Bend Radius = Cable Outer Diameter×Cable Multiplier. For example, if the outer diameter of a cable is 20mm, its minimum bending radius would be 20mm×6 = 120mm. Conversely, if an armored cable has an outer diameter of 30mm, its minimum bending radius would be 30mm×12 = 360mm.
Why do cable prices vary significantly among suppliers within the same region?
Cable prices vary due to differences in supplier strategies, competition, raw materials, and production processes, as well as after-sales services, including installation, equipment, and ongoing support.

Get in Touch With Our Team

Contact us for product information, cable selection, and project support.
Address: No. 1207 , Building B, No. 96 Kangning Street, Zhengdong New District, Zhengzhou City, China

    your Name

    your Email

    *

    Company Name

    *

    Country

    your Phone

    *

    WhatsApp No.

    Message

    *

    +86 371-63395670
    [email protected]
    +86 13938540747
    Engineered for Excellence, Certified for Reliability – Power Cables That Meet IEC, ANATEL & INMETRO Standards Globally

      X