Medium voltage N2XSEBY cables for distribution networks,They are suitable for laying indoor,tunnel,cables trench and underground.It is able to bear external mechanical forces,but unable to bear heavy pulling force,it widely used in transformer stations,electric power plants and industrial plants.

Construction
  • Conductor:Copper,class 2,circular compacted conductors
  • Conductor screen:Non-metallic,semi-conducting compound
  • Insulation:Cross-linked polyethylene (XLPE)
  • Insulation screen:Non-metallic,semi-conducting compound
  • Metallic screen:Copper wire
  • Filler:Non-hygroscopic material
  • Inner sheath:Polyvinyl chloride(PVC)
  • Armour:Steel tape
  • Outer sheath:Polyvinyl chloride(PVC)
Main Characteristics
  • Good electrical and mechanical properties.
  • Minimal dielectric loss,high insulation resistance.
Specification

IEC60228 Conductors of Insulated Cables
IEC 60502-2 Power Cables with Extruded Insulation and Their Accessories for Rated Voltages from 1kV (Um=1.2KV)up to 30kV(Um=36kV)-Part 2:Cables for Rated Voltages of 6kV(Um=7.2KV)up to 30kV (Um=36kV).

Share:

Product Parameters

No.of Cores and Nominal Cross Section Nominal Insulation Thickness Nominal Steel Tape Thickness Nominal Sheath Thickness Approx. Overall Diameter Approx.Weight Max.D.C.Resistance of Conductor at 20℃
Cu Al Cu Al
mm² mm mm mm mm kg/km kg/km Ω/km Ω/km
3×25 3.4 0.5 2.4 48.4 3324 2864 0.727 1.2
3×35 3.4 0.5 2.5 51 3771 3133 0.524 0.868
3×50 3.4 0.5 2.6 53.6 4272 3409 0.387 0.641
3×70 3.4 0.5 2.7 57.7 5119 3870 0.268 0.443
3×95 3.4 0.5 2.8 61.7 6102 4371 0.193 0.32
3×120 3.4 0.5 2.9 64.7 7014 4824 0.153 0.253
3×150 3.4 0.5 3.1 68.6 8341 5635 0.124 0.206
3×185 3.4 0.5 3.2 72.4 9664 6255 0.0991 0.164
3×240 3.4 0.5 3.4 78.0 11607 7183 0.0754 0.125
3×300 3.4 0.5 3.5 83.2 13641 8097 0.0601 0.100
3×400 3.4 0.8 3.8 91.2 17873 10730 0.047 0.0778
3×500 3.4 0.8 4.0 99.3 21480 12413 0.0366 0.0605
3×630 3.4 0.8 4.3 108.1 26178 14406 0.0283 0.0469

Application and case display

FAQ

Flame Retardant Cables VS Fire Resistant Cables?
What is the purpose of a metallic shield in MV and HV cables?
Why do cable prices vary significantly among suppliers within the same region?
Armored vs. Unarmored Cables?
How Do Water-Blocking Cables Work?
What is the minimum order quantity for the product?
The minimum order quantity for low and medium voltage cables is 200 meters, whereas for high voltage cables, it is 2000 meters. Should the order quantity fall below the MOQ, however, if the factory has stock, we can still supply it.
What are the weight limits for different types of packages?
The weight limit for a wooden drum or steel wooden is 5,000 kg, and for a steel drum, it is 10,000 kg.
What are the benefits of EPR material?
EPR is widely used as an insulation material for electric cables due to its high dielectric strength, and it also serves as a sheathing material with excellent ozone and weathering resistance. EPR has a wide thermal range, typically spanning from -55°C to 150°C. Unlike other organic rubbers, there is no need to tin the copper conductor to prevent deterioration of the rubber.
How do you calculate the minimum bending radius of cables?
The bend radius refers to the curved shape in which an electrical cable can be bent or curved without sustaining damage. To determine the minimum bend radius for cables, apply the following formula: Minimum Bend Radius = Cable Outer Diameter×Cable Multiplier. For example, if the outer diameter of a cable is 20mm, its minimum bending radius would be 20mm×6 = 120mm. Conversely, if an armored cable has an outer diameter of 30mm, its minimum bending radius would be 30mm×12 = 360mm.
What is the validity period for the offer of cable?
Typically, the offer is valid for 7 to 30 days, and the price will be adjusted according to the cost of raw materials and the exchange rate.

Get in Touch With Our Team

We're here to answer any questions you may have about our products, services, or technical specifications.
Address: No. 1207, Building B, No. 96 Kangning Street, Zhengdong New District, Zhengzhou, China

    your Name

    your Email

    *

    Company Name

    *

    Country

    your Phone

    *

    WhatsApp No.

    Message

    *



    +86 371-63395670
    info@starsunelectric.com
    +86 13938540747
    Engineered for Excellence, Certified for Reliability – Power Cables That Meet IEC, ANATEL & INMETRO Standards Globally



      X