Home > Medium Voltage Power Cables > N2XSRY 6/10kV Single Core Copper XLPE CTS AWA PVC MV Cable
N2XSRY
N2XSRY

N2XSRY 6/10kV Single Core Copper XLPE CTS AWA PVC MV Cable

Application

Medium voltage N2XSRY cables for distribution networks.They are suitable for laying Indoor,tunnel,cable trench,shaft or buried laying,The cable can withstand mechanical external forces and a certain tensile force,it widely used in transformer stations,electric power plants and industrial plants.

Construction
  • Conductor: Copper ,class 2,circular compacted conductors
  • Conductor screen: Non-metallic,semi-conducting compound
  • Insulation: Cross-Linked polyethylene(XLPE)
  • Insulation screen: Non-metallic,semi-conducting compound
  • Metallic screen: Copper tape
  • Inner sheath: Polyvinyl chloride(PVC)
  • Armour: Aluminum wire
  • Outer sheath: Polyvinyl chloride(PVC)
Main Characteristics
  • Good electrical and mechanical properties.
  • Minimal dielectric loss,high insulation resistance.
Specification

IEC 60228 Conductors of Insulated Cables.
IEC 60502-2 Power Cables with Extruded Insulation and Their Accessories for Rated Voltages from1kV (Um=1.2kV) up to 30kV (Um=36kV)-Part 2: Cables for Rated Voltages from 6kV (Um=7.2kV) up to 30kV (Um=36kV)

Share:

Product Parameters

No.of Cores  and Nominal  Cross Section Nominal  Insulation Thickness Nominal Aluminum Wire Diameter Nominal Sheath Thickness Approx. Overall Diameter Approx.
Weight
Max.D.C.
Resistance of Conductor at 20℃
Cu Al Cu Al
mm² mm mm mm mm kg/km kg/km Ω/km Ω/km
1×25 3.4 1.6 1.8 25.3 942 789 0.727 1.2
1×35 3.4 1.6 1.8 26.3 1071 860 0.524 0.868
1×50 3.4 1.6 1.8 27.4 1226 940 0.387 0.641
1×70 3.4 1.6 1.9 29.3 1496 1082 0.268 0.443
1×95 3.4 1.6 1.9 31.1 1809 1235 0.193 0.32
1×120 3.4 2 2 33.3 2167 1440 0.153 0.253
1×150 3.4 2 2.1 35.0 2502 1605 0.124 0.206
1×185 3.4 2 2.1 36.7 2909 1779 0.0991 0.164
1×240 3.4 2 2.2 39.2 3533 2066 0.0754 0.125
1×300 3.4 2 2.3 41.6 4192 2353 0.0601 0.1
1×400 3.4 2.5 2.4 45.7 5264 2895 0.047 0.0778
1×500 3.4 2.5 2.5 49.3 6397 3390 0.0366 0.0605
1×630 3.4 2.5 2.6 53.4 7930 4025 0.0283 0.0469

Application and case display

FAQ

Longitudinal Water Blocking vs. Lateral Water Blocking?
What is the application of Armored vs. Unarmored Cables?
What are low-smoke zero-halogen flame-retardant polyolefin cable compounds?
Why do cable prices vary significantly among suppliers within the same region?
What is the minimum order quantity for the product?
Longitudinal Water Blocking vs. Lateral Water Blocking?
A longitudinally water blocking cable is designed with a barrier to prevent the spread of moisture along its length. Longitudinal water blocking stops water from migrating along the cable's core, typically between the conductor strands, insulation layers, or metallic screens. Lateral water blocking ensures that water cannot penetrate the cable in the event that the sheathing is pierced or damaged. Radial water blocking prevents water from penetrating the cable's outer sheath or insulation layers, thereby stopping it from entering the cable structure entirely. Longitudinal water blocking can be achieved through various methods, including the application of water-blocking tapes and powders. These are frequently located on either side of a metallic screen and conductor. Lateral water blocking is typically accomplished by applying a layer of aluminum/polyester tape to the underside of the outer sheath.
What is the application of Armored vs. Unarmored Cables?
Armored cables are suitable for use in hazardous environments, such as underground installations, areas with high moisture levels, and areas prone to mechanical damage. Unarmored cables are suitable for less demanding applications, such as inside walls or other protected locations.
What are low-smoke zero-halogen flame-retardant polyolefin cable compounds?
They are environmentally friendly cable compounds used in the wire and cable industry. They are developed to provide low smoke, zero halogen and flame-retardant characteristics in cable applications.
Why do cable prices vary significantly among suppliers within the same region?
Cable prices vary due to differences in supplier strategies, competition, raw materials, and production processes, as well as after-sales services, including installation, equipment, and ongoing support.
What is the minimum order quantity for the product?
The minimum order quantity for low and medium voltage cables is 200 meters, whereas for high voltage cables, it is 2000 meters. Should the order quantity fall below the MOQ, however, if the factory has stock, we can still supply it.

Get in Touch With Our Team

Contact us for product information, cable selection, and project support.
Address: No. 1207 , Building B, No. 96 Kangning Street, Zhengdong New District, Zhengzhou City, China

    your Name

    your Email

    *

    Company Name

    *

    Country

    your Phone

    *

    WhatsApp No.

    Message

    *

    +86 371-63395670
    [email protected]
    +86 13938540747
    Engineered for Excellence, Certified for Reliability – Power Cables That Meet IEC, ANATEL & INMETRO Standards Globally