Home > Medium Voltage Power Cables > N2XSRY 8.7/15 (17.5) kV Copper XLPE insulated Aluminum wire armored Cable
N2XSRY-Cable
N2XSRY-Cable

N2XSRY 8.7/15 (17.5) kV Copper XLPE insulated Aluminum wire armored Cable

Application

Medium voltage N2XSRY cables for distribution networks.They are suitable for laying Indoor,tunnel,cable trench,shaft or buried laying,The cable can withstand mechanical external forces and a certain tensile force,it widely used in transformer stations,electric power plants and industrial plants.

Construction
  • Conductor: Copper ,class 2,circular compacted conductors
  • Conductor screen: Non-metallic,semi-conducting compound
  • Insulation: Cross-Linked polyethylene(XLPE)
  • Insulation screen: Non-metallic,semi-conducting compound
  • Metallic screen: Copper tape
  • Inner sheath: Polyvinyl chloride(PVC)
  • Armour: Aluminum wire
  • Outer sheath: Polyvinyl chloride(PVC)
Main Characteristics
  • Good electrical and mechanical properties.
  • Minimal dielectric loss,high insulation resistance.
Specification

IEC 60228 Conductors of Insulated Cables.
IEC 60502-2 Power Cables with Extruded Insulation and Their Accessories for Rated Voltages from1kV (Um=1.2kV) up to 30kV (Um=36kV)-Part 2: Cables for Rated Voltages from 6kV (Um=7.2kV) up to 30kV (Um=36kV)

Share:

Product Parameters

No.of Cores  and Nominal  Cross Section Nominal  Insulation Thickness Nominal Aluminum Wire Diameter Nominal Sheath Thickness Approx. Overall Diameter Approx.
Weight
Max.D.C.
Resistance of Conductor at 20℃
Cu Al Cu Al
mm² mm mm mm mm kg/km kg/km Ω/km Ω/km
1×25 4.5 1.6 1.8 27.7 1075 922 0.727 1.2
1×35 4.5 1.6 1.9 28.9 1215 1004 0.524 0.868
1×50 4.5 1.6 1.9 30 1381 1094 0.387 0.641
1×70 4.5 1.6 2 31.9 1658 1244 0.268 0.443
1×95 4.5 2 2.1 34.7 2070 1496 0.193 0.32
1×120 4.5 2 2.1 35.9 2350 1623 0.153 0.253
1×150 4.5 2 2.1 37.4 2667 1769 0.124 0.206
1×185 4.5 2 2.2 39.3 3106 1976 0.0991 0.164
1×240 4.5 2 2.3 41.8 3732 2265 0.0754 0.125
1×300 4.5 2 2.3 44.0 4390 2551 0.0501 0.100
1×400 4.5 2.5 2.5 48.3 5501 3132 0.047 0.0778
1×500 4.5 2.5 2.6 52.1 6672 3665 0.0366 0.0605
1×630 4.5 2.5 2.7 56 8199 4295 0.0283 0.0469

Application and case display

FAQ

What is the minimum order quantity for the product?
What is the validity period for the offer of cable?
What is the service life of cables?
What are the benefits of EPR material?
Armored vs. Unarmored Cables?
What is the service life of cables?
The design life of power cables is typically 20 to 30 years; however, this can vary significantly based on factors such as installation, environmental conditions, and the quality of the cable.
What is the application of Armored vs. Unarmored Cables?
Armored cables are suitable for use in hazardous environments, such as underground installations, areas with high moisture levels, and areas prone to mechanical damage. Unarmored cables are suitable for less demanding applications, such as inside walls or other protected locations.
What is the operating temperature of the cable?
The operating temperature of a cable is determined by the insulation and sheathing material. PVC has a range of -15°C to 70°C, XLPE can reach up to 90°C, while silicone rubber can handle temperatures from -60°C to 180°C.
Longitudinal Water Blocking vs. Lateral Water Blocking?
A longitudinally water blocking cable is designed with a barrier to prevent the spread of moisture along its length. Longitudinal water blocking stops water from migrating along the cable's core, typically between the conductor strands, insulation layers, or metallic screens. Lateral water blocking ensures that water cannot penetrate the cable in the event that the sheathing is pierced or damaged. Radial water blocking prevents water from penetrating the cable's outer sheath or insulation layers, thereby stopping it from entering the cable structure entirely. Longitudinal water blocking can be achieved through various methods, including the application of water-blocking tapes and powders. These are frequently located on either side of a metallic screen and conductor. Lateral water blocking is typically accomplished by applying a layer of aluminum/polyester tape to the underside of the outer sheath.
How long is the validity period of cold shrink cable accessories?
The validity period for most cold shrink cable accessories is typically 3 years from the date of manufacture, provided they are stored under recommended conditions. These conditions usually include controlled humidity and temperature ranges.

Get in Touch With Our Team

We're here to answer any questions you may have about our products, services, or technical specifications.
Address: No. 1207, Building B, No. 96 Kangning Street, Zhengdong New District, Zhengzhou, China

    your Name

    your Email

    *

    Company Name

    *

    Country

    your Phone

    *

    WhatsApp No.

    Message

    *



    +86 371-63395670
    info@starsunelectric.com
    +86 13938540747
    Engineered for Excellence, Certified for Reliability – Power Cables That Meet IEC, ANATEL & INMETRO Standards Globally



      X