N2XSY 6/10 (12) kV Copper XLPE insulated Copper tape shielded Cable

Application

Medium voltage cables for distribution networks,also for connection to generation units and plant and process connection.To be laid directly in ground,outdoors,indoors and in cable ducts.

Construction
  • Conductor: Copper ,class 2,circular compacted conductors
  • Conductor screen: Non-metallic,semi – conducting compound
  • Insulation: Cross -linked polyethylene (XLPE)
  • Insulation screen: Non-metallic,semi-conducting compound
  • Metallic screen: Copper tape
  • Outer sheath: Polyvinyl chloride(PVC)
Main Characteristics
  • Good electrical and mechanical properties.
  • Minimal dielectric loss,high insulation resistance.
Specification

IEC 60228 Conductors of Insulated Cables.
Rated Voltages: from 6kV(Um=7.2kV) up to 30kV (Um=36kV)

Share:

Product Parameters

No.of Cores  and Nominal Cross Section Nominal  insulation Thickness Nominal Sheath Thickness Approx Overall Diameter Approx.Weight Max.D.C. Resistance of Conductor at 20℃
Cu AI Cu AI
mm² mm mm mm kg/km kg/km Ω/km Ω/km
1×25 3.4 1.6 19.3 569 417 0.727 1.2
1×35 3.4 1.6 20.3 680 469 0.524 0.868
1×50 3.4 1.6 21.4 816 530 0.387 0.641
1×70 3.4 1.7 23.3 1054 640 0.268 0.443
1×95 3.4 1.7 25.1 1332 758 0.193 0.32
1×120 3.4 1.8 26.5 1592 866 0.153 0.253
1×150 3.4 1.8 28.0 1875 978 0.124 0.206
1×185 3.4 1.9 29.9 2265 1135 0.0991 0.164
1×240 3.4 2.0 32.4 2834 1367 0.0754 0.125
1×300 3.4 2.0 34.6 3432 1593 0.0601 0.100
1×400 3.4 2.2 37.7 4302 1933 0.047 0.0778
1×500 3.4 2.2 41.1 5332 2325 0.0366 0.0605
1×630 3.4 2.4 45.2 6760 2855 0.0283 0.0469

Application and case display

FAQ

What are the benefits of EPR material?
How long is the validity period of cold shrink cable accessories?
What is the minimum order quantity for the product?
Flame Retardant Cables VS Fire Resistant Cables?
What is the operating temperature of the cable?
What is the length tolerance for cables?
The tolerance for the power cable is 0 to +0.5%. For the bare conductor, the tolerance is ±5%.
What is the operating temperature of the cable?
The operating temperature of a cable is determined by the insulation and sheathing material. PVC has a range of -15°C to 70°C, XLPE can reach up to 90°C, while silicone rubber can handle temperatures from -60°C to 180°C.
Flame Retardant Cables VS Fire Resistant Cables?
Both types of cables are crucial in enhancing the likelihood of escape and survival in the event of a fire and are often confused with one another. However, there is a fundamental distinction between flame retardant cables and fire resistant cables. Flame retardant cables are engineered to inhibit the spread of fire to adjacent areas. On the other hand, fire resistant cables are specifically designed to preserve circuit integrity and ensure functionality during a fire, under specified conditions, aiding both evacuees and firefighters.
What is the minimum order quantity for the product?
The minimum order quantity for low and medium voltage cables is 200 meters, whereas for high voltage cables, it is 2000 meters. Should the order quantity fall below the MOQ, however, if the factory has stock, we can still supply it.
What are the weight limits for different types of packages?
The weight limit for a wooden drum or steel wooden is 5,000 kg, and for a steel drum, it is 10,000 kg.

Get in Touch With Our Team

We're here to answer any questions you may have about our products, services, or technical specifications.
Address: No. 1207, Building B, No. 96 Kangning Street, Zhengdong New District, Zhengzhou, China

    your Name

    *

    your Email

    *

    your Phone

    your Whatsapp

    *

    Country

    Products&service

    Message

    *



    +86 371-63395670
    info@starsunelectric.com
    +86 19137160160
    Engineered for Excellence, Certified for Reliability – Power Cables That Meet IEC, ANATEL & INMETRO Standards Globally



      X