Home > Low Voltage Power Cables > NA2XRY Multicore 0.6/1kV Aluminum XLPE insulated Steel wire armored Cable
Multicores NA2XRY Cable
Multicores NA2XRY Cable
Multicores NA2XRY Cable
Multicores NA2XRY Cable

NA2XRY Multicore 0.6/1kV Aluminum XLPE insulated Steel wire armored Cable

Application

These power cables are used for electricity supply in low voltage installation systems. They are well adapted to underground use in industrial applications with an additional mechanical protection. They are suitable for laying Indoor, tunnel, cable trench, shaft or buried laying. The cable can withstand mechanical external forces and a certain tensile force, it widely used in transformer stations, electric power plants and industrial plants.

Construction
  • Conductor: Aluminum, class 1 or class 2, solid or stranded, circular or circular compacted conductors
  • Insulation: Cross-linked polyethylene XLPE
  • Filler: Non-hygroscopic material
  • Binder: Non-hygroscopic material
  • Inner sheath: Polyvinyl chloride PVC
  • Armour: Steel wire
  • Binder: Non-hygroscopic material
  • Outer sheath: Polyvinyl chloride PVC
Main Characteristics
  • Good electrical and mechanical properties.
  • Cross-linked polyethylene insulation allows greater power capacity under any operating condition, minimum dielectric losses, high insulation resistance.
  • The PVC outer sheath allows an adequate resistance to oil and abrasion.
Specification

IEC 60228 Conductors of insulate cables
IEC 60502-1 Power cables with extruded insulation and their accessories for rated voltages from 1 kV(Um=1.2 kV) up to 30 kV(Um=36 kV) – Part 1: Cables for rated voltages of 1 kV (Um=1.2 kV) and 3 kV(Um=3.6 kV)

Share:

Product Parameters

No. of cores and nominal cross section Min. Number of wires Nominal insulation thickness Nominal steel wire diameter Nominal sheath thickness Approx. overall Diameter Approx. weight Max. DC resistance of conductor at 20℃
No.×mm2 No. mm mm mm mm kg/km Ω/km
2×2.5 1 0.7 0.8 1.8 14.1 314 12.1
2×4 1 0.7 0.8 1.8 15.1 357 7.41
2×6 1 0.7 0.8 1.8 16.1 406 4.61
2×10 6 0.7 1.25 1.8 19.5 619 3.08
2×16 6 0.7 1.25 1.8 21.1 743 1.91
2×25 6 0.9 1.6 1.8 25 1078 1.2
2×35 6 0.9 1.6 1.8 27 1243 0.868
2×50 6 1 1.6 1.8 30 1459 0.641
2×70 12 1.1 1.6 2 33.8 1796 0.443
2×95 15 1.1 2 2.1 39.1 2495 0.32
2×120 15 1.2 2 2.2 42.5 2836 0.253
2×150 15 1.4 2 2.3 46.5 3330 0.206
2×185 30 1.6 2.5 2.5 52.3 4386 0.164
2×240 30 1.7 2.5 2.7 57.7 5192 0.125
2×300 30 1.8 2.5 2.8 63.1 6049 0.1
2×400 53 2 2.5 3.1 70.1 7194 0.0778
3×2.5 1 0.7 0.8 1.8 14.6 340 12.1
3×4 1 0.7 0.8 1.8 15.6 388 7.41
3×6 1 0.7 0.8 1.8 16.7 448 4.61
3×10 6 0.7 1.25 1.8 20.4 682 3.08
3×16 6 0.7 1.25 1.8 22.1 835 1.91
3×25 6 0.9 1.6 1.8 26.2 1221 1.2
3X35 6 0.9 1.6 1.8 28.4 1414 0.868
3×50 6 1 1.6 1.9 31.8 1681 0.641
3×70 12 1.1 2 2 37.2 2389 0.443
3×95 15 1.1 2 2.2 41.5 2895 0.32
3×120 15 1.2 2 2.3 45.2 3336 0.253
3×150 15 1.4 2.5 2.5 51.1 4415 0.206
3×185 30 1.6 2.5 2.6 55.6 5113 0.164
3×240 30 1.7 2.5 2.8 61.8 6188 0.125
3×300 30 1.8 2.5 3 67.4 7206 0.1
3×400 53 2 2.5 3.2 74.7 8623 0.0778
4×2.5 1 0.7 0.8 1.8 15.4 377 12.1
4×4 1 0.7 0.8 1.8 16.6 436 7.41
4×6 1 0.7 1.25 1.8 18.7 631 4.61
4×10 6 0.7 1.25 1.8 21.8 779 3.08
4×16 6 0.7 1.6 1.8 24.4 1076 1.91
4×25 6 0.9 1.6 1.8 28.3 1404 1.2
4×35 6 0.9 1.6 1.9 30.9 1645 0.868
4×50 6 1 1.6 2 34.7 1977 0.641
4×70 12 1.1 2 2.2 40.7 2829 0.443
4×95 15 1.1 2 2.3 45.3 3434 0.32
4×120 15 1.2 2.5 2.5 51 4442 0.253
4×150 15 1.4 2.5 2.6 55.8 5198 0.206
4×185 30 1.6 2.5 2.8 61.4 6194 0.164
4×240 30 1.7 2.5 3 67.9 7424 0.125
4×300 30 1.8 2.5 3.2 74.1 8695 0.1
4×400 53 2 3.15 3.5 84.1 11526 0.0778
5×2.5 1 0.7 0.8 1.8 16.3 419 12.1
5×4 1 0.7 1.25 1.8 18.5 606 7.41
5×6 1 0.7 1.25 1.8 19.9 704 4.61
5×10 6 0.7 1.25 1.8 23.3 870 3.08
5×16 6 0.7 1.6 1.8 26.1 1227 1.91
5×25 6 0.9 1.6 1.8 30.5 1597 1.2
5×35 6 0.9 1.6 1.9 33.4 1890 0.868
5×50 6 1 2 2.1 39.3 2609 0.641
5×70 12 1.1 2 2.3 44.3 3271 0.443
5×95 15 1.1 2.5 2.5 51 4494 0.32
5×120 15 1.2 2.5 2.6 55.5 5148 0.253
5×150 15 1.4 2.5 2.8 61.4 6181 0.206
5×185 30 1.6 2.5 3 67.2 7236 0.164
5×240 30 1.7 2.5 3.2 74.4 8761 0.125
5×300 30 1.8 3.15 3.4 82.9 11266 0.1
5×400 53 2 3.15 3.8 92.4 13590 0.0778
3×4+1×2.5 1/1 0.7/0.7 0.8 1.8 16.3 422 7.41/12.1
3×6+1×4 1/1 0.7/0.7 1.25 1.8 18.4 608 4.61/7.41
3×10+1×6 6/1 0.7/0.7 1.25 1.8 21 736 3.08/4.61
3×16+1×10 6/6 0.7/0.7 1.25 1.8 23.2 905 1.91/3.08
3×25+1×16 6/6 0.9/0.7 1.6 1.8 27.3 1321 1.20/1.91
3×35+1×16 6/6 0.9/0.7 1.6 1.8 29.1 1489 0.868/1.91
3×50+1×25 6/6 1.0/0.9 1.6 1.9 33 1831 0.641/1.20
3×70+1×35 12/6 1.1/0.9 2 2.1 38.6 2584 0.443/0.868
3×95+1×50 15/6 1.1/1.0 2 2.2 43 3114 0.320/0.641
3×120+1×70 15/12 1.2/1.1 2 2.4 47.3 3683 0.253/0.443
3×150+1×70 15/12 1.4/1.1 2.5 2.5 52.4 4719 0.206/0.443
3×185+1×95 30/15 1.6/1.1 2.5 2.7 57.5 5527 0.164/0.320
3×240+1×120 30/15 1.7/1.2 2.5 2.9 63.8 6672 0.125/0.253
3×300+1×150 30/15 1.8/1.4 2.5 3 69.5 7800 0.100/0.206
3×400+1×185 53/30 2.0/1.6 3.15 3.3 78.8 10313 0.0778/0.164
3×4+2×2.5 1/1 0.7/0.7 1.25 1.8 18 577 7.41/12.1
3×6+2×4 1/1 0.7/0.7 1.25 1.8 19.3 660 4.61/7.41
3×10+2×6 6/1 0.7/0.7 1.25 1.8 21.9 807 3.08/4.61
3×16+2×10 6/6 0.7/0.7 1.6 1.8 25.3 1138 1.91/3.08
3×25+2×16 6/6 0.9/0.7 1.6 1.8 28.7 1450 1.20/1.91
3×35+2×16 6/6 0.9/0.7 1.6 1.8 30.4 1614 0.868/1.91
3×50+2×25 6/6 1.0/0.9 2 2 36.4 2285 0.641/1.20
3×70+2×35 12/6 1.1/0.9 2 2.1 40.4 2814 0.443/0.868
3×95+2×50 15/6 1.1/1.0 2 2.3 45.4 3436 0.320/0.641
3×120+2×70 15/12 1.2/1.1 2.5 2.5 51.6 4566 0.253/0.443
3×150+2×70 15/12 1.4/1.1 2.5 2.6 54.9 5099 0.206/0.443
3×185+2×95 30/15 1.6/1.1 2.5 2.8 60.9 6138 0.164/0.320
3×240+2×120 30/15 1.7/1.2 2.5 3 67 7316 0.125/0.253
3×300+2×150 30/15 1.8/1.4 2.5 3.2 73.4 8591 0.100/0.206
3×400+2×185 53/30 2.0/1.6 3.15 3.5 83 11345 0.0778/0.164
4×4+1×2.5 1/1 0.7/0.7 1.25 1.8 18.2 587 7.41/12.1
4×6+1×4 1/1 0.7/0.7 1.25 1.8 19.6 682 4.61/7.41
4×10+1×6 6/1 0.7/0.7 1.25 1.8 22.6 838 3.08/4.61
4×16+1×10 6/6 0.7/0.7 1.6 1.8 25.7 1182 1.91/3.08
4×25+1×16 6/6 0.9/0.7 1.6 1.8 29.6 1515 1.20/1.91
4×35+1×16 6/6 0.9/0.7 1.6 1.9 32 1750 0.868/1.91
4×50+1×25 6/6 1.0/0.9 2 2.1 38 2485 0.641/1.20
4×70+1×35 12/6 1.1/0.9 2 2.2 42.4 3054 0.443/0.868
4×95+1×50 15/6 1.1/1.0 2 2.4 47.5 3726 0.320/0.641
4×120+1×70 15/12 1.2/1.1 2.5 2.5 53.4 4843 0.253/0.443
4×150+1×70 15/12 1.4/1.1 2.5 2.7 57.9 5608 0.206/0.443
4×185+1×95 30/15 1.6/1.1 2.5 2.9 64 6702 0.164/0.320
4×240+1×120 30/15 1.7/1.2 2.5 3.1 70.7 8012 0.125/0.253
4×300+1×150 30/15 1.8/1.4 3.15 3.3 79 10410 0.100/0.206
4×400+1×185 53/30 2.0/1.6 3.15 3.6 87.6 12438 0.0778/0.164

Application and case display

FAQ

What is the length tolerance for cables?
What is the service life of cables?
What are the weight limits for different types of packages?
How Do Water-Blocking Cables Work?
What is the operating temperature of the cable?
What is the length tolerance for cables?
The tolerance for the power cable is 0 to +0.5%. For the bare conductor, the tolerance is ±5%.
How do you calculate the minimum bending radius of cables?
The bend radius refers to the curved shape in which an electrical cable can be bent or curved without sustaining damage. To determine the minimum bend radius for cables, apply the following formula: Minimum Bend Radius = Cable Outer Diameter×Cable Multiplier. For example, if the outer diameter of a cable is 20mm, its minimum bending radius would be 20mm×6 = 120mm. Conversely, if an armored cable has an outer diameter of 30mm, its minimum bending radius would be 30mm×12 = 360mm.
What temperature can high-temperature resistant cables reach, and what are their application scenarios?
High-temperature resistant cables are engineered to function within a wide temperature range, spanning from -50°C to +260°C, depending on the cable's specific type and construction. Silicone rubber-insulated cables can withstand temperatures up to 180°C, whereas fluoroplastic insulated cables are designed to endure temperatures as high as 200°C to 260°C over extended periods. They are widely used in steel metallurgy, power, petrochemicals, aerospace, and industrial kilns for power transmission and equipment control in high-heat environments.
What is the service life of cables?
The design life of power cables is typically 20 to 30 years; however, this can vary significantly based on factors such as installation, environmental conditions, and the quality of the cable.
What is the purpose of a metallic shield in MV and HV cables?
Medium and high voltage power cables, typically those in circuits exceeding 2kV, usually feature a shield layer made of copper or aluminum tape. Similar to their use in low voltage cables, metallic wires and tapes are employed to prevent electromagnetic interference. These shields effectively neutralize or significantly diminish the field currents surrounding the conductor or core. The capacitive and inductive charging currents induced under normal operating conditions are subsequently grounded by the metallic screen.

Get in Touch With Our Team

We're here to answer any questions you may have about our products, services, or technical specifications.
Address: No. 1207, Building B, No. 96 Kangning Street, Zhengdong New District, Zhengzhou, China

    your Name

    *

    your Email

    *

    your Phone

    your Whatsapp

    *

    Country

    Products&service

    Message

    *



    +86 371-63395670
    info@starsunelectric.com
    +86 19137160160
    Engineered for Excellence, Certified for Reliability – Power Cables That Meet IEC, ANATEL & INMETRO Standards Globally



      X