Home > Medium Voltage Power Cables > NA2XSERY Three Core 12/20 (24) kV Aluminum XLPE insulated Steel wire armored Cable
NA2XSERY
NA2XSERY

NA2XSERY Three Core 12/20 (24) kV Aluminum XLPE insulated Steel wire armored Cable

Application

Medium voltage NA2XSERY cables for distribution networks. They are suitable for laying indoor, tunnel, cable trench, shaft or buried laying. The cable can withstand mechanical external forces and a certain tensile force, it widely used in transformer stations, electric power plants and industrial plants.

Construction
  • Conductor: Aluminum, class 2, circular compacted conductors
  • Conductor screen: Non-metallic, semi-conducting compound
  • Insulation: Cross-linked polyethylene (XLPE)
  • Insulation screen: Non-metallic, semi-conducting compound
  • Metallic screen: Copper tape screen
  • Filler: Non-hygroscopic material
  • Inner sheath: Polyvinyl chloride (PVC)
  • Armour: Steel wire
  • Outer sheath: Polyvinyl chloride (PVC)
Main Characteristics
  • Good electrical and mechanical properties.
  • Minimal dielectric loss, high insulation resistance.
Specification

IEC 60228 Conductors of Insulated Cables
IEC 60502-2 Power Cables with Extruded Insulation and Their Accessories for Rated Voltages from 1kV (Um=1.2kV) up to 30kV (Um=36kV)-Part2: Cables for Rated Voltages from 6kV (Um=7.2kV) up to 30kV (Um=36kV).

Share:

Product Parameters

No.of Cores and Nominal Cross Section Nominal Insulation Thickness Nominal Steel Wire Diameter Nominal Sheath Thickness Approx. Overall Diameter Approx.Weight Max.D.C. Resistance of Conductor at 20℃
Cu Al Cu Al
mm2 mm mm mm mm kg/km kg/km Ω/km Ω/km
3×35 5.5 2.5 2.9 60.7 5853 5215 0.524 0.868
3×50 5.5 2.5 3 63.5 6507 5644 0.387 0.641
3×70 5.5 2.5 3.1 67.4 7489 6241 0.268 0.443
3×95 5.5 2.5 3.2 71.6 8708 6977 0.193 0.32
3×120 5.5 3.15 3.4 76.1 10666 8477 0.153 0.253
3×150 5.5 3.15 3.5 79.6 11879 9173 0.124 0.206
3×185 5.5 3.15 3.6 83.6 13462 10054 0.0991 0.164
3×240 5.5 3.15 3.8 89.2 15715 11292 0.0754 0.125
3×300 5.5 3.15 3.9 94.4 18203 12659 0.0601 0.100
3×400 5.5 3.15 4.2 101.0 21443 14300 0.047 0.0778
3×500 5.5 3.15 4.4 109.1 25601 16535 0.0366 0.0605
3×630 5.5 3.15 4.6 117.9 30717 18944 0.0283 0.0469

Application and case display

FAQ

What’s the difference between H05RN-F and H07RN-F?
How Do Water-Blocking Cables Work?
What are the weight limits for different types of packages?
Longitudinal Water Blocking vs. Lateral Water Blocking?
What is the validity period for the offer of cable?
What’s the difference between H05RN-F and H07RN-F?
H05RN-F is a 300/500V rubber cable for light-duty indoor tools and household equipment. H07RN-F is a 450/750V heavy-duty cable for industrial machines, construction sites, and outdoor power use. Both comply with EN 50525 standards.
How Do Water-Blocking Cables Work?
Water-blocking cables are essential for ensuring reliable operation in environments with high levels of moisture or frequent water contact. These cables employ water-blocking techniques to effectively prevent water ingress, protecting them from damage and prolonging their lifespan.
What are the weight limits for different types of packages?
The weight limit for a wooden drum or steel wooden is 5,000 kg, and for a steel drum, it is 10,000 kg.
Longitudinal Water Blocking vs. Lateral Water Blocking?
A longitudinally water blocking cable is designed with a barrier to prevent the spread of moisture along its length. Longitudinal water blocking stops water from migrating along the cable's core, typically between the conductor strands, insulation layers, or metallic screens. Lateral water blocking ensures that water cannot penetrate the cable in the event that the sheathing is pierced or damaged. Radial water blocking prevents water from penetrating the cable's outer sheath or insulation layers, thereby stopping it from entering the cable structure entirely. Longitudinal water blocking can be achieved through various methods, including the application of water-blocking tapes and powders. These are frequently located on either side of a metallic screen and conductor. Lateral water blocking is typically accomplished by applying a layer of aluminum/polyester tape to the underside of the outer sheath.
What is the validity period for the offer of cable?
Typically, the offer is valid for 7 to 30 days, and the price will be adjusted according to the cost of raw materials and the exchange rate.

Get in Touch With Our Team

Contact us for product information, cable selection, and project support.
Address: No. 1207 , Building B, No. 96 Kangning Street, Zhengdong New District, Zhengzhou City, China

    your Name

    your Email

    *

    Company Name

    *

    Country

    your Phone

    *

    WhatsApp No.

    Message

    *

    +86 371-63395670
    [email protected]
    +86 13938540747
    Engineered for Excellence, Certified for Reliability – Power Cables That Meet IEC, ANATEL & INMETRO Standards Globally

      X