Home > Medium Voltage Power Cables > NA2XSY 6/10 (12) kV Aluminum XLPE insulated Copper tape shielded Cable
NA2XSY-Cable
NA2XSY-Cable

NA2XSY 6/10 (12) kV Aluminum XLPE insulated Copper tape shielded Cable

Application

Medium voltage cables for distribution networks, also for connection to generation units and plant and process connection. To be laid directly in ground,outdoors, indoors and in cable ducts.

Construction
  • Conductor: Aluminum, class 2, circular compacted conductors
  • Conductor screen: Non-metallic, semi-conducting compound
  • Insulation: Cross-linked polyethylene (XLPE)
  • Insulation screen: Non-metallic, semi-conducting compound
  • Metallic screen: Copper tape
  • Outer sheath: Polyvinyl chloride (PVC)
Main Characteristics
  • Good electrical and mechanical properties.
  • Minimal dielectric loss, high insulation resistance.
Specification

IEC 60228 Conductors of Insulated Cables.
Rated Voltages: from 6kV (Um=7.2kV) up to 30kV (Um=36kV)

Share:

Product Parameters

No.of Cores and Nominal Cross Section Nominal  Insulation Thickness Nominal Sheath Thickness Approx Overall Diameter Approx.Weight Max.D.C. Resistance of Conductor at 20℃
Cu AI Cu AI
mm² mm mm mm kg/km kg/km Ω/km Ω/km
1×25 3.4 1.6 19.3 569 417 0.727 1.2
1×35 3.4 1.6 20.3 680 469 0.524 0.868
1×50 3.4 1.6 21.4 816 530 0.387 0.641
1×70 3.4 1.7 23.3 1054 640 0.268 0.443
1×95 3.4 1.7 25.1 1332 758 0.193 0.32
1×120 3.4 1.8 26.5 1592 866 0.153 0.253
1×150 3.4 1.8 28.0 1875 978 0.124 0.206
1×185 3.4 1.9 29.9 2265 1135 0.0991 0.164
1×240 3.4 2.0 32.4 2834 1367 0.0754 0.125
1×300 3.4 2.0 34.6 3432 1593 0.0601 0.100
1×400 3.4 2.2 37.7 4302 1933 0.047 0.0778
1×500 3.4 2.2 41.1 5332 2325 0.0366 0.0605
1×630 3.4 2.4 45.2 6760 2855 0.0283 0.0469

Application and case display

FAQ

How Do Water-Blocking Cables Work?
How long is the validity period of cold shrink cable accessories?
What is the operating temperature of the cable?
Longitudinal Water Blocking vs. Lateral Water Blocking?
What are the benefits of EPR material?
Longitudinal Water Blocking vs. Lateral Water Blocking?
A longitudinally water blocking cable is designed with a barrier to prevent the spread of moisture along its length. Longitudinal water blocking stops water from migrating along the cable's core, typically between the conductor strands, insulation layers, or metallic screens. Lateral water blocking ensures that water cannot penetrate the cable in the event that the sheathing is pierced or damaged. Radial water blocking prevents water from penetrating the cable's outer sheath or insulation layers, thereby stopping it from entering the cable structure entirely. Longitudinal water blocking can be achieved through various methods, including the application of water-blocking tapes and powders. These are frequently located on either side of a metallic screen and conductor. Lateral water blocking is typically accomplished by applying a layer of aluminum/polyester tape to the underside of the outer sheath.
Is a flame-retardant cable also fire resistant?
No. A flame-retardant cable is not the same as a fire-resistant cable. A flame-retardant cable is designed to restrict the spread of fire by inhibiting combustion. Fire-resistant cables, on the other hand, maintain circuit integrity and continue to function for a specified time under defined fire conditions.
What are the benefits of EPR material?
EPR is widely used as an insulation material for electric cables due to its high dielectric strength, and it also serves as a sheathing material with excellent ozone and weathering resistance. EPR has a wide thermal range, typically spanning from -55°C to 150°C. Unlike other organic rubbers, there is no need to tin the copper conductor to prevent deterioration of the rubber.
What are the weight limits for different types of packages?
The weight limit for a wooden drum or steel wooden is 5,000 kg, and for a steel drum, it is 10,000 kg.
How long is the validity period of cold shrink cable accessories?
The validity period for most cold shrink cable accessories is typically 3 years from the date of manufacture, provided they are stored under recommended conditions. These conditions usually include controlled humidity and temperature ranges.

Get in Touch With Our Team

We're here to answer any questions you may have about our products, services, or technical specifications.
Address: No. 1207, Building B, No. 96 Kangning Street, Zhengdong New District, Zhengzhou, China

    your Name

    *

    your Email

    *

    your Phone

    your Whatsapp

    *

    Country

    Products&service

    Message

    *



    +86 371-63395670
    info@starsunelectric.com
    +86 19137160160
    Engineered for Excellence, Certified for Reliability – Power Cables That Meet IEC, ANATEL & INMETRO Standards Globally