Application

These power cables are used for electricity supply in low voltage installation systems. They are well adapted to underground use in industrial applications with an additional mechanical protection. These cables can be fixed on cable trays, within conduits or fixed to walls.

Construction
  • Conductor: Aluminum, class 1 or class 2, solid or stranded, circular or circular compacted conductors
  • Insulation: Cross-linked polyethylene XLPE
  • Filler: Non-hygroscopic material
  • Binder: Non-hygroscopic material
  • Outer sheath: Polyvinyl chloride PVC
Main Characteristics
  • Good electrical and mechanical properties.
  • Cross-linked polyethylene insulation allows greater power capacity under any operating condition, minimum dielectric losses, high insulation resistance.
  • The PVC outer sheath allows an adequate resistance to oil and abrasion.
Specification

IEC 60228 Conductors of insulate cables
IEC 60502-1 Power cables with extruded insulation and their accessories for rated voltages from 1 kV(Um=1.2 kV) up to 30 kV(Um=36 kV) – Part 1: Cables for rated voltages of 1 kV (Um=1.2 kV) and 3 kV(Um=3.6 kV)

Share:

Product Parameters

No. of cores and nominal cross section Min. Number of wires Nominal insulation thickness Nominal sheath thickness Approx. overall Diameter Approx. weight Max. DC resistance of conductor at 20℃
No.×mm2 No. mm mm mm kg/km Ω/km
2×2.5 1 0.7 1.8 10.2 103 12.1
2×4 1 0.7 1.8 11.2 124 7.41
2×6 1 0.7 1.8 12.2 150 4.61
2×10 6 0.7 1.8 14.7 199 3.08
2×16 6 0.7 1.8 16.3 263 1.91
2×25 6 0.9 1.8 19.5 372 1.2
2×35 6 0.9 1.8 21.5 461 0.868
2×50 6 1 1.8 24.5 582 0.641
2×70 12 1.1 1.8 27.9 754 0.443
2×95 15 1.1 2 32.2 1007 0.32
2×120 15 1.2 2.1 35.6 1224 0.253
2×150 15 1.4 2.2 39.6 1508 0.206
2×185 30 1.6 2.3 43.8 1855 0.164
2×240 30 1.7 2.5 49.2 2374 0.125
2×300 30 1.8 2.7 54.4 2919 0.1
2×400 53 2 2.9 61.2 3692 0.0778
3×2.5 1 0.7 1.8 10.7 118 12.1
3×4 1 0.7 1.8 11.7 144 7.41
3×6 1 0.7 1.8 12.8 177 4.61
3×10 6 0.7 1.8 15.6 238 3.08
3×16 6 0.7 1.8 17.3 319 1.91
3×25 6 0.9 1.8 20.7 459 1.2
3X35 6 0.9 1.8 22.9 575 0.868
3×50 6 1 1.8 26.1 733 0.641
3×70 12 1.1 1.9 30.3 992 0.443
3×95 15 1.1 2 34.4 1297 0.32
3×120 15 1.2 2.1 38.1 1586 0.253
3×150 15 1.4 2.3 42.6 1973 0.206
3×185 30 1.6 2.4 47.1 2434 0.164
3×240 30 1.7 2.6 52.9 3123 0.125
3×300 30 1.8 2.8 58.5 3849 0.1
3×400 53 2 3.1 66 4908 0.0778
4×2.5 1 0.7 1.8 11.5 137 12.1
4×4 1 0.7 1.8 12.7 170 7.41
4×6 1 0.7 1.8 13.9 211 4.61
4×10 6 0.7 1.8 17 287 3.08
4×16 6 0.7 1.8 18.9 390 1.91
4×25 6 0.9 1.8 22.8 567 1.2
4×35 6 0.9 1.8 25.2 715 0.868
4×50 6 1 1.9 29 929 0.641
4×70 12 1.1 2 33.6 1262 0.443
4×95 15 1.1 2.1 38.2 1654 0.32
4×120 15 1.2 2.3 42.5 2044 0.253
4×150 15 1.4 2.4 47.3 2517 0.206
4×185 30 1.6 2.6 52.5 3133 0.164
4×240 30 1.7 2.8 59 4021 0.125
4×300 30 1.8 3 65.2 4955 0.1
4×400 53 2 3.3 73.5 6316 0.0778
5×2.5 1 0.7 1.8 12.4 159 12.1
5×4 1 0.7 1.8 13.7 198 7.41
5×6 1 0.7 1.8 15.1 249 4.61
5×10 6 0.7 1.8 18.5 340 3.08
5×16 6 0.7 1.8 20.6 466 1.91
5×25 6 0.9 1.8 25 682 1.2
5×35 6 0.9 1.8 27.7 865 0.868
5×50 6 1 2 32.4 1149 0.641
5×70 12 1.1 2.1 37.2 1550 0.443
5×95 15 1.1 2.3 42.5 2053 0.32
5×120 15 1.2 2.4 47 2513 0.253
5×150 15 1.4 2.6 52.5 3119 0.206
5×185 30 1.6 2.8 58.3 3879 0.164
5×240 30 1.7 3 65.5 4976 0.125
5×300 30 1.8 3.2 72.3 6131 0.1
5×400 53 2 3.6 81.8 7846 0.0778
3×4+1×2.5 1/1 0.7/0.7 1.8 12.4 162 7.41/12.1
3×6+1×4 1/1 0.7/0.7 1.8 13.6 201 4.61/7.41
3×10+1×6 6/1 0.7/0.7 1.8 16.2 268 3.08/4.61
3×16+1×10 6/6 0.7/0.7 1.8 18.4 364 1.91/3.08
3×25+1×16 6/6 0.9/0.7 1.8 21.8 521 1.20/1.91
3×35+1×16 6/6 0.9/0.7 1.8 23.6 630 0.868/1.91
3×50+1×25 6/6 1.0/0.9 1.8 27.3 826 0.641/1.20
3×70+1×35 12/6 1.1/0.9 1.9 31.5 1111 0.443/0.868
3×95+1×50 15/6 1.1/1.0 2.1 36.1 1472 0.320/0.641
3×120+1×70 15/12 1.2/1.1 2.2 40.2 1838 0.253/0.443
3×150+1×70 15/12 1.4/1.1 2.3 43.9 2188 0.206/0.443
3×185+1×95 30/15 1.6/1.1 2.5 49 2751 0.164/0.320
3×240+1×120 30/15 1.7/1.2 2.7 54.9 3508 0.125/0.253
3×300+1×150 30/15 1.8/1.4 2.9 60.8 4332 0.100/0.206
3×400+1×185 53/30 2.0/1.6 3.1 68.2 5476 0.0778/0.164
3×4+2×2.5 1/1 0.7/0.7 1.8 13.2 182 7.41/12.1
3×6+2×4 1/1 0.7/0.7 1.8 14.5 228 4.61/7.41
3×10+2×6 6/1 0.7/0.7 1.8 17.1 303 3.08/4.61
3×16+2×10 6/6 0.7/0.7 1.8 19.8 415 1.91/3.08
3×25+2×16 6/6 0.9/0.7 1.8 23.2 593 1.20/1.91
3×35+2×16 6/6 0.9/0.7 1.8 24.9 700 0.868/1.91
3×50+2×25 6/6 1.0/0.9 1.9 29.5 949 0.641/1.20
3×70+2×35 12/6 1.1/0.9 2 35.2 1266 0.443/0.868
3×95+2×50 15/6 1.1/1.0 2.2 38.5 1674 0.320/0.641
3×120+2×70 15/12 1.2/1.1 2.3 43.1 2122 0.253/0.443
3×150+2×70 15/12 1.4/1.1 2.4 46.4 2466 0.206/0.443
3×185+2×95 30/15 1.6/1.1 2.6 52 3121 0.164/0.320
3×240+2×120 30/15 1.7/1.2 2.8 58.1 3962 0.125/0.253
3×300+2×150 30/15 1.8/1.4 3 64.5 4896 0.100/0.206
3×400+2×185 53/30 2.0/1.6 3.2 72.2 6175 0.0778/0.164
4×4+1×2.5 1/1 0.7/0.7 1.8 13.4 190 7.41/12.1
4×6+1×4 1/1 0.7/0.7 1.8 14.8 238 4.61/7.41
4×10+1×6 6/1 0.7/0.7 1.8 17.8 322 3.08/4.61
4×16+1×10 6/6 0.7/0.7 1.8 20.2 441 1.91/3.08
4×25+1×16 6/6 0.9/0.7 1.8 24.1 638 1.20/1.91
4×35+1×16 6/6 0.9/0.7 1.8 26.3 782 0.868/1.91
4×50+1×25 6/6 1.0/0.9 1.9 30.9 1045 0.641/1.20
4×70+1×35 12/6 1.1/0.9 2.1 35.5 1414 0.443/0.868
4×95+1×50 15/6 1.1/1.0 2.2 40.4 1853 0.320/0.641
4×120+1×70 15/12 1.2/1.1 2.4 45.1 2326 0.253/0.443
4×150+1×70 15/12 1.4/1.1 2.5 49.4 2788 0.206/0.443
4×185+1×95 30/15 1.6/1.1 2.7 55.1 3495 0.164/0.320
4×240+1×120 30/15 1.7/1.2 2.9 61.8 4463 0.125/0.253
4×300+1×150 30/15 1.8/1.4 3.1 68.4 5507 0.100/0.206
4×400+1×185 53/30 2.0/1.6 3.4 77 7000 0.0778/0.164

Application and case display

FAQ

What temperature can high-temperature resistant cables reach, and what are their application scenarios?
How long is the validity period of cold shrink cable accessories?
What is the operating temperature of the cable?
What is the service life of cables?
What is the validity period for the offer of cable?
What is the operating temperature of the cable?
The operating temperature of a cable is determined by the insulation and sheathing material. PVC has a range of -15°C to 70°C, XLPE can reach up to 90°C, while silicone rubber can handle temperatures from -60°C to 180°C.
What is the service life of cables?
The design life of power cables is typically 20 to 30 years; however, this can vary significantly based on factors such as installation, environmental conditions, and the quality of the cable.
Flame Retardant Cables VS Fire Resistant Cables?
Both types of cables are crucial in enhancing the likelihood of escape and survival in the event of a fire and are often confused with one another. However, there is a fundamental distinction between flame retardant cables and fire resistant cables. Flame retardant cables are engineered to inhibit the spread of fire to adjacent areas. On the other hand, fire resistant cables are specifically designed to preserve circuit integrity and ensure functionality during a fire, under specified conditions, aiding both evacuees and firefighters.
Armored vs. Unarmored Cables?
Armored cables are ideal for direct burial and laying underground, offering protection against environmental factors. Unarmored cables are unsuitable for burial or use in other challenging applications and installations.
Is a flame-retardant cable also fire resistant?
No. A flame-retardant cable is not the same as a fire-resistant cable. A flame-retardant cable is designed to restrict the spread of fire by inhibiting combustion. Fire-resistant cables, on the other hand, maintain circuit integrity and continue to function for a specified time under defined fire conditions.

Get in Touch With Our Team

We're here to answer any questions you may have about our products, services, or technical specifications.
Address: No. 1207, Building B, No. 96 Kangning Street, Zhengdong New District, Zhengzhou, China

    your Name

    *

    your Email

    *

    your Phone

    your Whatsapp

    *

    Country

    Products&service

    Message

    *



    +86 371-63395670
    info@starsunelectric.com
    +86 19137160160
    Engineered for Excellence, Certified for Reliability – Power Cables That Meet IEC, ANATEL & INMETRO Standards Globally



      X