Home > Low Voltage Power Cables > RZ1-K XLPE insulated LSZH Cable
RV-K-Cable
RV-K-Cable

RZ1-K XLPE insulated LSZH Cable

Application

For installations where fire, smoke emissions, and toxic fumes pose potential threats to life and equipment, a flexible power and control cable designed for fixed applications is manufactured. It features flexible conductors to facilitate installations with sinuous courses.

Construction

Conductor: Class 5 flexible copper conductor

Insulation: XLPE (Cross-Linked Polyethylene)

Sheath: LSZH (Low Smoke Zero Halogen)

Specification

IEC 60502-1 Power Cables with Extruded Insulation and Their Accessories for Rated Voltages from 1kV (Um=1.2KV) up to 30kV (Um=36KV) – Part1: Cables for Rated Voltages of 1kV (Um=1.2KV) and 3kV (Um=3.6kV)

EN 60228 Conductors of insulated cables

UNE 21123-4 Industrial cables of rated voltage 0.6/1kV – Part 4: XLPE insulated and polyolefin sheathed cables

Share:

Product Parameters

No. of cores and nominal cross section Conductor diameter Nominal insulation thickness Approx. overall diameter Approx. weight Max. DC resistance of conductor at 20°C
No.× mm2 mm mm mm kg/km Ω/km
1×1.5 1.60 0.7 5.9 48 13.3
1×2.5 2.02 0.7 6.3 61 7.98
1×4 2.59 0.7 6.9 79 4.95
1×6 3.17 0.7 7.5 102 3.3
1×10 4.10 0.7 8.4 146 1.91
1×16 5.50 0.7 10.4 222 1.21
1×25 6.70 0.9 12.0 322 0.78
1×35 8.20 0.9 13.5 426 0.554
1×50 10.00 1.0 15.5 583 0.386
1×70 11.60 1.1 17.3 784 0.272
1×95 13.00 1.1 18.9 1030 0.206
1×120 14.40 1.2 20.5 1275 0.161
1×150 16.20 1.4 22.9 1588 0.129
1×185 18.20 1.6 25.6 1954 0.106
1×240 20.60 1.7 28.4 2499 0.0801
1×300 23.40 1.8 31.4 3084 0.0641
1×400 26.60 2.0 35.4 4076 0.0486
1×500 30.00 2.2 39.4 5065 0.0384
1×630 34.00 2.4 44.0 6340 0.0287
2×1.5 1.60 0.7 10.4 128 13.3
2×2.5 2.02 0.7 11.2 158 7.98
2×4 2.59 0.7 12.3 203 4.95
2×6 3.17 0.7 13.5 259 3.3
2×10 4.10 0.7 15.4 361 1.91
2×16 5.50 0.7 18.2 520 1.21
2×25 6.70 0.9 21.4 754 0.78
2×35 8.20 0.9 24.6 1022 0.554
2×50 10.00 1.0 28.6 1397 0.386
2×70 11.60 1.1 32.2 1862 0.272
2×95 13.00 1.1 35.4 2426 0.206
2×120 14.40 1.2 38.8 3003 0.161
2×150 16.20 1.4 43.5 3740 0.129
2×185 18.20 1.6 48.5 4598 0.106
2×240 20.60 1.7 54.2 5874 0.0801
2×300 23.40 1.8 60.6 7302 0.0641
2×400 26.60 2.0 68.2 9561 0.0486
3×1.5 1.60 0.7 10.9 149 13.3
3×2.5 2.02 0.7 11.8 190 7.98
3×4 2.59 0.7 13.0 250 4.95
3×6 3.17 0.7 14.2 323 3.3
3×10 4.10 0.7 16.3 464 1.91
3×16 5.50 0.7 19.3 678 1.21
3×25 6.70 0.9 22.8 999 0.78
3×35 8.20 0.9 26.2 1358 0.554
3×50 10.00 1.0 30.5 1870 0.386
3×70 11.60 1.1 34.7 2538 0.272
3×95 13.00 1.1 37.9 3310 0.206
3×120 14.40 1.2 41.5 4113 0.161
3×150 16.20 1.4 46.7 5147 0.129
3×185 18.20 1.6 52.2 6337 0.106
3×240 20.60 1.7 58.2 8107 0.0801
3×300 23.40 1.8 65.1 10080 0.0641
3×400 26.60 2.0 73.5 13285 0.0486
4×1.5 1.60 0.7 11.7 176 13.3
4×2.5 2.02 0.7 12.7 229 7.98
4×4 2.59 0.7 14.0 304 4.95
4×6 3.17 0.7 15.5 401 3.3
4×10 4.10 0.7 17.7 579 1.91
4×16 5.50 0.7 21.1 856 1.21
4×25 6.70 0.9 25.2 1293 0.78
4×35 8.20 0.9 28.8 1733 0.554
4×50 10.00 1.0 33.9 2418 0.386
4×70 11.60 1.1 38.5 3285 0.272
4×95 13.00 1.1 42.1 4299 0.206
4×120 14.40 1.2 46.3 5370 0.161
4×150 16.20 1.4 51.9 6692 0.129
4×185 18.20 1.6 58.2 8267 0.106
4×240 20.60 1.7 64.9 10583 0.0801
4×300 23.40 1.8 72.6 13158 0.0641
4×400 26.60 2.0 81.9 17347 0.0486
5×1.5 1.60 0.7 12.5 205 13.3
5×2.5 2.02 0.7 13.7 270 7.98
5×4 2.59 0.7 15.2 363 4.95
5×6 3.17 0.7 16.8 482 3.3
5×10 4.10 0.7 19.3 702 1.91
5×16 5.50 0.7 23.0 1041 1.21
5×25 6.70 0.9 27.6 1581 0.78
5×35 8.20 0.9 31.7 2128 0.554
5×50 10.00 1.0 37.5 2989 0.386
5×70 11.60 1.1 42.6 4065 0.272
5×95 13.00 1.1 46.8 5348 0.206
5×120 14.40 1.2 51.3 6657 0.161
5×150 16.20 1.4 57.7 8325 0.129
5×185 18.20 1.6 64.6 10274 0.106
5×240 20.60 1.7 72.1 13159 0.0801
5×300 23.40 1.8 80.6 16355 0.0641
5×400 26.60 2.0 91.2 21614 0.0486

 

 

Application and case display

FAQ

What is the minimum order quantity for the product?
What is the length tolerance for cables?
What are the weight limits for different types of packages?
What is the minimum order quantity for the product?
The minimum order quantity for low and medium voltage cables is 200 meters, whereas for high voltage cables, it is 2000 meters. Should the order quantity fall below the MOQ, however, if the factory has stock, we can still supply it.
What is the length tolerance for cables?
The tolerance for the power cable is 0 to +0.5%. For the bare conductor, the tolerance is ±5%.
What are the weight limits for different types of packages?
The weight limit for a wooden drum or steel wooden is 5,000 kg, and for a steel drum, it is 10,000 kg.

Get in Touch With Our Team

We're here to answer any questions you may have about our products, services, or technical specifications.
Address: No. 1207, Building B, No. 96 Kangning Street, Zhengdong New District, Zhengzhou, China

    your Name

    *

    your Email

    *

    your Phone

    your Whatsapp

    *

    Country

    Products&service

    Message

    *



    +86 371-63395670
    info@starsunelectric.com
    +86 19137160160
    Engineered for Excellence, Certified for Reliability – Power Cables That Meet IEC, ANATEL & INMETRO Standards Globally



      X